Rs-232C Command Table - Sharp PN-70HC1E Operation Manual

Hide thumbs Also See for PN-70HC1E:
Table of Contents

Advertisement

RS-232C command table

How to read the command table
Command:
Command field (See page 37.)
Direction:
W When the "Parameter" is set in the parameter field (see page 37), the command functions as described
under "Control/Response Contents".
R The returned value indicated under "Reply" can be obtained by setting "????" or "
parameter field. (See page 37.)
Parameter:
Parameter field (See page 37.)
Reply:
Response (Returned value)
TIPS
• In the standby mode, the only command that is used is Power control.
Power control/Input mode selection
Function
Power control
Input mode selection
* You can use "Wake On LAN (Magic Packet)" to turn on the power via LAN.
It is not possible to turn on the monitor with the IP Control command.
Image menu
Function
BRIGHT
SIZE (Screen size selection)
Settings menu
Function
VOLUME
MUTE AUDIO
Controlling the Monitor with a computer (RS-232C)
Command Direction
Parameter
POWR
W
0
1
R
INPS
W
0
2
3
4
10
13
16
18
21
24
R
Command Direction
Parameter
VLMP
WR
0-100
WIDE
W
0
WR
1-3
Command Direction
Parameter
VOLM
WR
0-100
MUTE
WR
0-1
Reply
Control/Response contents
Switches to standby mode.
Returns from standby mode.*
0 Standby mode
1 Normal mode
Toggle change for input mode.
VGA1
YPBPR
AV
HDMI 1
HDMI 2
VGA2
HDMI 3
OPS
"ERR" when nothing is attached in the expansion slot.
APPLICATION
2 VGA1
3 YPBPR
4 AV
10 HDMI 1
13 HDMI 2
16 VGA2
18 HDMI 3
21 OPS
24 APPLICATION
Reply
Control/Response contents
0-100
0 Toggle change for screen size.
1-3 1: 16:9, 2: Dot by Dot, 3: 4:3
Reply
Control/Response contents
0-100
0-1 0: OFF, 1: ON
?" in the
39
E

Advertisement

Table of Contents
loading

Table of Contents