Loctite CL10 Operation Manual

Quad led controller
Hide thumbs Also See for CL10:

Advertisement

Quick Links

EQUIPMENT
Operation Manual
Loctite
CL10 Quad LED Controller
Part Number 1514634

Advertisement

Table of Contents
loading

Summary of Contents for Loctite CL10

  • Page 1 EQUIPMENT Operation Manual  Loctite CL10 Quad LED Controller Part Number 1514634...
  • Page 2: Table Of Contents

    Contents CAUTION························································································· 4 1.1 S ···································································· 5 AFETY NSTRUCTION 1.2 O ································································ 5 UT OF NSPECTION 1.3 P ·············································································· 6 ACKING LIST OVERVIEW ······················································································ 6 TECHNICAL DATA············································································ 7 INSTALLATION ················································································ 8 4.1 C ·················································································· 8 APACITY 4.2 D ················································································· 9 IMENSION 4.3 C ··················································································...
  • Page 3 5.10 L ·································································· 32 ANGUAGE ETTING 5.11 LED H ··············································· 33 NIT AND WITCH 5.12 S ············································································ 34 HUTDOWN TROUBLESHOOTING······································································ 35 REPLACEMENT PARTS ·································································· 37 : APPENDIX DIMENSION ································································· 38 : APPENDIX PLC I/O ····································································· 39 10 WARRANTY··················································································· 40...
  • Page 4: Caution

    Caution Info: 【Warning instructions in this manual and on labels are classified as described below.】 WARNING: This means that possible death or serious injury to the operator may result if these instruction are ignored and the equipment is handled incorrectly. Forbidden: This symbol means that the instruction describes prohibited item or actions.
  • Page 5: Safety Instruction

     In the case of an abnormal condition, stop using the equipment immediately. 1.2 Out of Box Inspection Open Loctite® CL10 Quad LED Controller package carefully and check if components were damaged during delivery. Please inform carrier if unit is damaged.
  • Page 6: Packing List

    97201 Foot Switch Q1 Adapter Overview Loctite CL10 Quad LED Controller, the UV light source is in accordance with JIS C6802 “LED Safety Standard”, LED product classifications: 3B, wavelength: 365 or 405nm, meets the requirement of UV curing in Optical, Electronic, Optical Fiber, communication and printing industry.
  • Page 7: Technical Data

    Technical Data Type 1514634 Intensity (0%~100%), Time (0.1~999.9 C.C. seconds) Manual Intensity (0%~100%), Time: Manual control MODE Lens bonding 10 steps, each step can define intensity and STEP time independently. Intensity (0~100%) , Time (Max.999.9 seconds) Power Supply AC100-220V 50/60Hz MAX 1.5A Power consumption Cooling method...
  • Page 8: Installation

    Installation Please check the unit for any mechanical defects. If there is any breakage due to delivery, please stop using equipment and return to supplier. 4.1 Capacity CL10 Quad LED Controller Power MODE START STOP Minimum space required for the equipment.
  • Page 9: Dimension

    4.2 Dimensions CL10 Quad LED Controller Power MODE START STOP SERVICE RS232 Serial No. Item No. 1514634 Input: 100~240VAC, 50/60 Hz Rated Power: 30 W AC 100~240V 50/60Hz MAX 0.6A Henkel China Company Limited FUSE: 3 AMP 240VAC No.928 Zhangeheng Rd. Pudong.
  • Page 10: Caution

    4.3 Caution  Set the unit horizontally on a level surface. Failure to do so can cause the equipment to stop working normally, over heat, or other damage can occur.  Avoid places with high voltage machinery.  Make sure nothing can be placed on power cable, and that it will not be reachable by the operator.
  • Page 11: Low

    4.4 Installation Flow Place the controller properly. Connect power cable to the controller, as pictured below. There are 4 LED head connectors on the back side of the controller named CH1, CH2, CH3, CH4. Connect LED heads one at a time. Align the groove on the main unit and red point on the LED head unit, with the cable plug.
  • Page 12 Connect foot switch(option) Step 1: ●Connect the adapter to controller Step 2: ●Connect foot switch to adapter. Caution: ● When connecting the adapter to the controller, be sure to align the numbers as shown above. Be sure to insert the connector fully. After finishing, symbol “CH1”,”CH2”,”CH3”,”CH4”...
  • Page 13 Connect PLC (Option) Note: ● To operate CH’s switch, press one time to turn on the LED head, press again to turn off. ● Output signal follow PLC standard level 0~24V ● 0V means LED head is working.
  • Page 14: Controller Button And Operating Panel

    Controller button and operating panel Component name and function PORT 1 PORT 2 CL10 Quad LED Controller SERVICE RS232 Power MODE START STOP Serial No. Item No. 1514634 Input: 100~240VAC, 50/60 Hz Rated Power: 30 W AC 100~240V 50/60Hz MAX 0.6A...
  • Page 15: Button And Operating Panel Instructions

    7. Control port:LED head control signal input. 8. LED head connector. 9. Power cable connector. 10. Service port. Button and operating panel instructions 5.2.1 Controller button instruction Mode/ESC:Back or exit menu without change Start/Stop:Enter or exit pre-irradiance mode. Arrow Keys:Move cursor up/down or left/right. SET Button:Confirm or enter menu.
  • Page 16: Lcd Display

    5.2.2 LCD Display Instruction <OK>:Confirm change. STEP <STEP>:Go to step panel. Version <Version>:To version information. Parameter <Parameter>:To Parameter panel. Langua <Language>:To language panel. <R/S>:Enter or exit Pre-irradiance mode. 5.2.3 Parameter cursor status unchangeable:Cursor is dark, means it cannot be changed. changeable:Cursor in half dark, means it can change mode and parameters through the arrow keys.
  • Page 17: Operation

    Error, has recovered Errors can happen with equipment due to incorrect operation, and can be recovered. If this happens frequently, please contact the manufacturer. Please re-set parameter Parameter missing due to interrupt or incorrect operation, please reset parameter. Please wait... Equipment is processing data, please wait.
  • Page 18: Ontroller

    5.3.2 Starting Controller Power After finishing installation, plug in power cable, then press . When the red Power LED light inside of turns on, the LCD will show processing as follows: To avoid incorrect operation, all buttons will be forbidden except ...
  • Page 19: Ode

    : 5.3.3 Working Mode  In working panel, move the cursor to ,pressing ,will enter working mode. <Working…> will show on display. At that time, you can control LED head by using a foot switch or PLC. : 5.3.4 Exit Working Mode ...
  • Page 20: Setting

    : 5.3.5 Standby Mode Setting ●Enter Parameter Panel ●Move cursor here ●Choose “Enable” and “Disable” by pressing the Up/Down arrow key. Note: ◆”Enable”——Controller will enter Pre-irradiance mode automatically during startup. ◆”Disable”——Controller can enter standby mode by operating manually. 5.3.6 Password setting in Parameter Panel When this panel is shown, key in the password as shown in the following step: ...
  • Page 21 Change password: ●Move cursor to “*”. ●After keying in password, press to change the password ●Change (0~9)by Up/Down arrow key,Change target by Left/Right arrow key. to confirm after keying in new password. After two ●Press times keying in, press , the password is changed. Note:...
  • Page 22: Etting

    Parameter Setting 5.4.1 Enter Parameter Panel 2.Press to enter <Menu>, 1.Move cursor to Parameter move cursor to 3.Press to enter parameter panel.
  • Page 23: Setup

    5.4.2 Working Mode Setup  Move cursor to the cell that is Chan. Mode under <Mode> C.C. STEP  Chan. Mode Press to change, cursor goes to half dark. 。 STEP  Chan. Mode Change mode type using arrow key. STEP...
  • Page 24  Press to confirm. Chan. Mode STEP  Move cursor to , then press to confirm change and save data.  Repeat the flow if needed to change other data in parameter panel.
  • Page 25: Working Mode 5.5.1 C.c Mode

    5.5 Working Mode Description 5.5.1 C.C Mode When selecting constant current mode, the associated head will work with a fixed intensity. The LED head starts working when pressing the foot switch, while the timer counts down. The LED head will stop working when the timer goes to zero.
  • Page 26: Parameter

    ( ) 5.6 Parameter Intensity Setting ●Move cursor to target cell. ●Press to change the status to 100% changeable. ●Edit data by up/down arrow keys, press left/right arrow keys to change unit, ten and hundred. ●Finish editing, press to confirm, cell 100% status goes to unchangeable ●Move cursor to...
  • Page 27: Etup

    : 5.7 Foot Switch Setup ●Move cursor to target cell ●Press to change the status to changeable ●Press up/down arrow key to edit data (1~4). ●Select related foot switch, press confirm. Data go to unchangeable. ●Move cursor to and press to save.
  • Page 28: Foot Switch S 5.8 Time Setting

    : 5.8 Time Setting Time range: 0.1s~999.9s ●Move cursor to target cell Note: ●Press to change the status to changeable If set time <0.0s, will change to 0.1s 010.0s automatically after confirm and save. In manual mode, ●Edit data by up/down arrow keys, press left/right time setting is not arrow key to change units, ten and hundred.
  • Page 29: Step Mode

    5.9 Step Mode In this mode, LED head will work step by step after process finishes. There are 10 steps in one action, time and power will follow each step’s setting in step panel. Setting flow: ●Enter Menu panel ●Move cursor to ●Press to step panel(as following picture)...
  • Page 30: Step Mode

    5.9.1 Time Setup in Step Mode ●Move cursor to target cell ●Press to change the status to changeable 002.0s ●Edit data by up/down arrow keys, press left/right arrow keys to change unit, ten and hundred. ●Select related foot switch, press to confirm.
  • Page 31: Etting

    5.9.2 Intensity Setting ●Move cursor to target cell ●Press to change the status to 010% changeable ●Edit data by up/down arrow keys, press left/right arrow keys to change unit, ten and hundred. ●Select related foot switch, press to confirm. Data goes to unchangeable 010% 。...
  • Page 32: Etting

    5.10 Language Setting ●Enter <Menu>. ●Move cursor to ●Press to language panel ●Move cursor to the language type that you want to select. ●Press to confirm. ●Press to go back to <Menu>.
  • Page 33: Led Head

    5.11 LED Head Unit and Foot Switch  Please measure and define working distance properly before using LED head. Don’t touch the head in use it may cause injury by high temperature.  ●Working panel will be shown during running. ●Click foot switch, LED head will work as set parameter...
  • Page 34: Shutdown

    Note: 5.12 Shutdown ●The equipment can run following timer setting. ●Intensity of LED head output can be adjusted, adjust range: 0%~100%. CL10 Quad LED Controller Power MODE START STOP Press power button to turn off controller, red indicator will turn...
  • Page 35: Troubleshooting

    Step 2:Disconnect power cable. Troubleshooting Error Cause/Demonstration Action Please check if power cable is plugged in Plug in power cable properly. 1.Display not on properly. when turning on power button Please check the fuse Fuse type:3AMP, 240VAC Please check if LED head Exit working status, enter is in working status.
  • Page 36 3.LED head Please check Go to parameter and set working equipment is working in mode as you want. abnormally. your required mode. Please check the LCD 4.No UV output Enter working panel and display in working panel, or make sure controller in pre- when clicking foot if it is in pre-irradiance irradiance status.
  • Page 37: Replacement Parts

    Replacement Parts Loctite® Name Item No. Controller CL10 Quad LED Controller 1514634 CL10 365nm 6mm LED Head, 2.7M Cable 1538499 Head CL10 405nm 6mm LED Head, 2.7M Cable 1746633 Spare Parts Lens CL10 365nm, 6mm LED Lens 1538496 CL10 405nm, 6mm LED Lens...
  • Page 38: Appendix

    : Appendix Dimension CL10 Quad LED Controller CL10 Quad LED Controller Power MODE START STOP SERVICE RS232 Serial No. Item No. 1514634 Input: 100~240VAC, 50/60 Hz Rated Power: 30 W AC 100~240V 50/60Hz MAX 0.6A Henkel China Company Limited FUSE: 3 AMP 240VAC No.928 Zhangeheng Rd.
  • Page 39: Plc I/O

    : Appendix PLC I/O Caution: ● To operate CH’s switch, press one time to turn on the LED head, press again to turn off. ● Output signal follow PLC standard level 0~24V. ● 0V effective Note: Q1 adapter is only for using foot switch to control. Please use PLC connector below when trying to connect a PLC and want to use PLC to control the controller.
  • Page 40: Warranty

    WARRANTY Henkel expressly warrants that all products referred to in this Instruction Manual for (1514634 Loctite® CL10 Quad LED Controller) (hereafter called “Products”) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, as its option, to replacing those Products which are shown to be defective...
  • Page 41 #03-01/02 Haw Par Technocentre Zhangjiang, Hi-Tech Park, Pudong, Loc. Tulpetlac, C.P. 55090 SINGAPORE 149598 Shanghai, China 201203 Ecatepac de Morelos, MEXICO Henkel Loctite Korea Henkel Japan Ltd. 8F, Mapo Tower, 418, 27-7 Shin Isogo-cho, Isogo-ku www.equipment.loctite.com Mapo-dong, Mapo-gu, Yokohama, 235-0017...

This manual is also suitable for:

1514634

Table of Contents