Loctite CL10 Operation Manual

Loctite CL10 Operation Manual

Led controller
Hide thumbs Also See for CL10:

Advertisement

EQUIPMENT
Operation Manual
CL10 Single LED Controller
Item No. 1514636
Intensity %
Time S
SET
Loctite
CL10 Single LED Controller
Item # 1514636

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CL10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Loctite CL10

  • Page 1 EQUIPMENT Operation Manual CL10 Single LED Controller Item No. 1514636 Intensity % Time S  Loctite CL10 Single LED Controller Item # 1514636...
  • Page 2: Table Of Contents

    Contents .................................... 1 Contents ................................2 1 Caution................................3 Safety Instruction..........................4 Out of Box Inspection........................4 Items Supplied ........................... 4 2 Overview ................................ 5 3 Technical Data .............................. 5 4 Installation ..............................6 4.1 Capacity..............................6 4.2 Dimension ............................... 6 Caution..............................
  • Page 3: Caution

    1 Caution Info: Warning instructions in this manual and on labels are classified and described below. WARNING: This means that possible death or serious injury to the operator may result if these instructions are ignored and the equipment handled incorrectly. Forbidden:This symbol means that the instruction describes prohibited item or action.
  • Page 4: Safety Instruction

     In case of an abnormal condition, stop using the equipment immediately. 1.2 Out of Box Inspection Open Loctite® CL10 Single LED Controller package carefully and check if any components were damaged during shipment. Please inform carrier if damage has occurred.
  • Page 5: Overview

    2 Overview Loctite® CL10 Single LED Controller is a UV light source that emits a spot of light at a wavelength of 365 or 405nm for use in adhesive Light Cure bonding applications. Advantage: 1. Over 20,000 working hours. 2. No IR emission resulting in low temperature curing. Will not damage parts due to heat emission.
  • Page 6: Installation

    Please check the unit for any mechanical defects. If there is any shipping damage do not install or use the equipment and immediately contact the shipping company and supplier. 4.1 Capacity Min .space required for the equipment 4.2 Dimension CL10 Single LED Controller Item No. 1514636 Intensity % Time S...
  • Page 7: Caution

    4.3 Caution  To prevent heat damage, set the unit horizontally on a level surface. Failure to position the unit properly may cause damage.  Avoid placing next to high voltage equipment or next to a heat source.  Make sure nothing is placed on the power cable. 4.4 Installation Flow Place the controller horizontally on a level surface.
  • Page 8: Controller Button And Operating

    Up arrow button SET Button:Confirm or enter menu. Down arrow button Power cable connector Control port:LED head control signal input. CL10 Single LED Controller Item No. 1514636 Intensity % XS-1 AC100~240V 50/60Hz Time S...
  • Page 9: Button And Display Instruction

    5.2 Button and Display Instruction 5.2.1 Button Instruction Power Power Switch:Power On/Off. Arrow buttons:Edit settings SET Button:Confirm or enter menu. 5.2.2 Display instruction Intensity % Intensity data information Time data information Time S 5.3 Operating 5.3.1 Startup Warning  Please place this equipment in a stable space. ...
  • Page 10: Starting Controller

    5.3.2 Starting Controller Power After finishing installation, plug in power cable, then press . The red LED Power light inside the button will turn on when the unit is powered. 5.3.3 Working Mode If the LED head is plugged in, the controller will automatically enter Working Mode.
  • Page 11: Working Mode Setting

    5.5 Working mode setting In Working Mode, you can switch Manual/Timer mode by holding button. In Timed Mode, the set time will be displayed. In manual mode, "oFF" will be displayed under Time S. 5.6 Working Temperature Press once while in working mode to show the temperature of the LED. Caution ...
  • Page 12: Shutdown

    6 Shutdown Step 1:Press Power button to turn off controller, red indicator will turn off at same time. Step 2:Disconnect power cable.
  • Page 13: Troubleshooting

    7 Troubleshooting Error Cause/Demonstration Action Please check if power Plug in power cable 1.Display not on cable is plugged in properly. when turning on properly. power button Please check the fuse Fuse type:2AMP, 250VAC Please check if LED head Exit working status, enter is in working status.
  • Page 14: Replacement Parts

    8 Replacement Parts Loctite® Name Item No. Controller CL10 Single LED Controller 1514636 CL10 LED Head, 365nm, 3mm, w/2.7m cable 1540715 CL10 LED Head, 365nm, 6mm, w/2.7m cable 1538499 CL10 LED Head, 365nm, 10mm, w/2.7m cable 1538505 LED Head CL10 LED Head, 365nm, 3mm, w/5m cable...
  • Page 15: Warranty

    Henkel expressly warrants that all products referred to in this Instruction Manual for Loctite® CL10 Single LED Controller (hereafter called “ Products” ) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, as its option,...
  • Page 16 #03-01/02 Haw Par Technocentre Zhangjiang, Hi-Tech Park, Pudong, Loc. Tulpetlac, C.P. 55090 SINGAPORE 149598 Shanghai, China 201203 Ecatepac de Morelos, MEXICO Henkel Loctite Korea Henkel Japan Ltd. 8F, Mapo Tower, 418, 27-7 Shin Isogo-cho, Isogo-ku www.equipment.loctite.com Mapo-dong, Mapo-gu, Yokohama, 235-0017...