Note The operating instructions contain useful 2. Application Area information to make handling easier. The MT2 is a wet trimmer used for grinding plaster or acrylic models for dental technology applications. Wear eye protection. Ambient Conditions (in accordance with DIN EN 61010-1) For indoor use only.
13.Plug the unit’s power cord into the wall outlet. Liability Exclusion Renfert GmbH shall be absolved from all claims for The MT2 is now ready for use damages or warranty if: • The product is employed for any purposes other than those cited in the operating 5.
result in damage to the trimmer disc. following section). 7. Install the new trimmer disc (Figure 3). 8. Make sure the locking pins are properly seated in Never use the trimmer discs to grind the retention holes (Figure 3). metal. Muffle rings, pins, and retention rings, etc.
12. Troubleshooting Fault Cause Remedy The unit does not switch on. • The electricity supply is not • Check the electricity supply. properly connected. • The electrical safety device is • Check the safety device. defect. • The front lid is not closed •...