Page 4
30mm Posa della piastra di fondazione VE.P650 (opzionale) Foundation plate positioning VE.P650 (optional) Montage der Fundamentplatte VE.P650 (option) Mise en place de la plaque de fondation VE.P650 (optionnel) Posicionamiento de la placa de alimentación VE.P650 (opcional) Ułożenie płyty fundamentowej VE.P650 (opcjonalma)
Page 5
Slow-down Open (SLDo) Slow-down Close (SLDC) (SWC)
Page 7
SOSTITUZIONE MOLLA SPRING REPLACEMENT FRÜHLING-ERSATZ REMPLACEMENT DES RESSORTS REEMPLAZO DEL RESORTE WYMIANA SPRĘŻYNY ASSEMBLAGGIO ASTA 8M 8M ROD ASSEMBLY 8M STAB-MONTAGE TIGE ARTICULÉE 8M MONTAJE DE LA BARRA 8M 8M PRZY MONTAŻU TŁOCZYSKA...
Page 9
PHOTOTEST AUX1:0004 AUX1:0000 24Vdc tst1:on AUX1 AUX1 24Vdc PHOT 24Vac LAMP SERVICE LIGHT AUX1:0003 24Vdc 24Vac NC NO 24Vac AUX1 Relè 24Vdc 230Vac LAMP MASTER SLAVE Menu Menu ID=0 ID=1 3x0,5mm GND B A GND B A...
Page 10
Schema menu di programmazione - Menu programming layout Diagramm Programmiermenü - Menu de programmation Display OFF Menú de la carta de programación - Układ menu programowania Power ON v1. 0 5 Firmware Ver. (3s) 8888 Inst Boom Diagnostic IBCA 0--- ---0 fsts ltca...
Page 11
Nman 0012 3456 MACI 2 Cycle AUTO PUSH OPEN/CLOSE RE-ENTER CODE 0000 9000 9C5a conf CODE Display OFF Inst Legenda Premere il tasto (-) / Press key (-) / Die Taste (-) drücken Appuyez sur la touche (-) / Presionar la tecla (-) / Wcisnąć przycisk (-) PUSH Premere il tasto (+) / Press key (+) / Die Taste (+) drücken Appuyez sur la touche (+) / Presionar la tecla (+) / Wcisnąć...
Every utilization different from the one described in this instruction manual is not allowed and voids the manufacturer warranty. We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation updated for all the Benincà...
Conventionally it is considered right a barrier which seen from the side of the cabinet door, closes the passage by lowering the boom towards right. However it is possible to reverse the barrier movement and turn a right barrier into a left one by means of few easy operations (Fig. 3 B : EVA.8 LEFT).
13) CP.EVA2 CONTROL UNIT 13.1) WIRE DIAGRAM Wire connections shown in Fig. 13 are described hereunder: TERMINAL BLOCK M3 TERMINALS Function Description Connection for the antenna of the built in receiver (ANT-signal/SHIELD-shield). ANT-SHIELD Antenna In case of use of an external antenna it is necessary to remove the pre-cabled cable from the terminal ANT Auxiliary output AUX 1 Output with N.O.
13.3.2) PARAMETERS (PAR) MENU FUNCTION MIN-MAX-(Default) MEMO Automatic closing time. Enabled only with logic “TCA”=ON. 1-240-(20s) At the end of the set time, the control unit commands a closing maneuver . Adjusts the opening and closing speed of the barrier (standard speed, before the slowdown FSTS 50-99-(99) phase).
Enabled or disables HOLD-TO-RUN function On: HOLD-TO-RUN function. The pressure of the OPENS/CLOSES button must be maintained throughout the entire manoeuvre. (OFF) The opening of the STOP input stops the motor. All the safety inputs are deactivated. Off: Automatic/semiautomatic function Selects the operating mode of the blinking light during the time TCA ltca On: Blinking light on during TCA...
13.3.6) MAINTENANCE CYCLES (MACI) This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer. To activate and select the number of manoeuvres, proceed as follows: Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value). With the buttons <+>...
13.5) TRANSMITTERS REMOTE LEARNING If an already memorised transmitter is available in the receiver it is possible to carry out remote radio learning (without needing to access the control unit). IMPORTANT: the procedure must be carried out with barrier open.The logic REM must be ON. Proceed as follows: 1 Press the hidden key of the transmitter which is already memorised.
Page 20
EVA.8 USER’S HANDBOOK SAFETY MEASURES • Do not stand within the gate movement area. • Children must not play with controls and near the gate. • In the event of malfunctions, do not attempt to repair the failure but contact the specialised personnel.