INSTALLATION INSTRUCTIONS

INSTALLATION

WARNING: Make sure the unit is turned off and unplugged before working.
1
Cut the window sash foam seal (adhesive
type) to the proper length and attach it to
the underside of the window sash.
Insert the right closure assembly and the
2
left closure assembly into the top angle
and the bottom channels.
Secure the right and left closure to the
cabinet with six of the provided screws.
13
(L=
/
", 10mm)
32
3
Open the window sash and place the air
conditioner on the sill.
Balance the unit on the sill and close the
window sash securely behind the top
angle.
WARNING:
At this step, make sure the unit is inclined
approximately 1 cm (
If the unit is not properly inclined, the water
collected in the bottom tray during opera-
tion will not drain properly and may flow into
the room where the air conditioner is in-
stalled.
Insert the bottom gasket into the space
4
between the window sill and the bottom of
the unit to seal outside air.
If there is space between the bottom
channel and the sill, fill the gap with a thin
board or other hard filler.
6
3
/
") to the back.
8
Sash
Jamb
Sill
Closure assembly
sill
incline backwards approximately
1cm (
Bottom gasket
Window sash foam seal
(adhesive type)
unit
3
/
")
8