ORION ITALIA IPR-D Instruction Manual page 30

Ground protection relay
Table of Contents

Advertisement

AUX1 OUTPUT
RELAY: LATCHED
AUX1 RELAY PULSE
TIME: 0.2 Sec
If
"AUX1 OUTPUT RELAY"
=
PULSED
AUX2 OUTPUT
RELAY: LATCHED
AUX2 RELAY PULSE
TIME: 0.2 Sec
If
"AUX2 OUTPUT RELAY"
=
PULSED
AUX3 OUTPUT
RELAY: LATCHED
AUX3 RELAY PULSE
TIME: 0.2 Sec
If
"AUX2 OUTPUT RELAY"
=
PULSED
END OF PAGE
For AUX3 display the information at page 4.4 "OUT OF SERVICE ON AUX 3".
CURRENT PROTECTION RELAY - IPR-D
RANGE:
........................................................................................
• PULSED operation:
In case of fault condition due to which the related output must activate, this output will
be energized for a time as the one set in AUX1 RELAY PULSE TIME; after this time
the output relay will de-energize and the contact will return to the stand-by condition.
• LATCHED operation:
In case of fault condition due to which the related output must activate, this output will
be energized for an indefinite time. The output relay will de-energize only when the
fault condition is no more present and the unit is RESET.
RANGE:
.......................................................................................................
STEPS:
......................................................................................................................
Enter the delay for AUX 1 relay de-energizing.
RANGE:
........................................................................................
• PULSED operation:
In case of fault condition due to which the related output must activate, this output will
be energized for a time as the one set in AUX2 RELAY PULSE TIME; after this time
the output relay will de-energize and the contact will return to the stand-by condition.
• LATCHED operation:
In case of fault condition due to which the related output must activate, this output will
be energized for an indefinite time. The output relay will de-energize only when the
fault condition is no more present and the unit is RESET.
RANGE:
.......................................................................................................
STEPS:
......................................................................................................................
Enter the delay for AUX 2 relay de-energizing.
RANGE:
........................................................................................
• PULSED operation:
In case of fault condition due to which the related output must activate, this output will
be energized for a time as the one set in AUX3 RELAY PULSE TIME; after this time
the output relay will de-energize and the contact will return to the stand-by condition.
• LATCHED operation:
In case of fault condition due to which the related output must activate, this output will
be energized for an indefinite time. The output relay will de-energize only when the
fault condition is no more present and the unit is RESET.
RANGE:
.......................................................................................................
STEPS:
......................................................................................................................
Enter the delay for AUX 3 relay de-energizing.
Last LINE of PAGE 5.
Press LINE or ▲PAGE, to pass to the first line of PAGE 6.
4.6
Chapter 4: "SETPOINTS" Menu
LATCHED; PULSED
0.1 s ÷ 2.0 s
0.1 s
LATCHED; PULSED
1.0 s ÷ 2.0 s
0.1 s
LATCHED; PULSED
1.0 s ÷ 2.0 s
0.1 s
Manual P/N: IPR-D GBM 01/09/2006