Table of Contents

Advertisement

®
If you have a problem, question, or request, call
your local dealer, or Steelcase Line 1 at
888.STEELCASE (888.783.3522)
for immediate action by people who want to help you.
(Outside the U.S.A., Canada, Mexico, Puerto Rico,
and the U.S. Virgin Islands, call: 1.616.247.2500)
Or visit our website: www.steelcase.com
©
2018 Steelcase Inc.
Grand Rapids, MI 49501
U.S.A.
Printed in U.S.A.
This equipment has been tested and found to comply with the limits for a class B digital device pursuant
to Part 15 for FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the
separation between the equipment and receiver. • Connect the equipment into an outlet or a circuit different
from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician
for help.
This class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada
Mackinac Assembly Instructions
5mm
(M10&M8)
4mm
(M6)
#2
T-15
T-30
Felt Pad
(Included)
Page 1 of 71
1317809001 Rev A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mackinac and is the answer not in the manual?

Questions and answers

Summary of Contents for Steelcase Mackinac

  • Page 1: Title Page

    This equipment has been tested and found to comply with the limits for a class B digital device pursuant your local dealer, or Steelcase Line 1 at to Part 15 for FCC rules. These limits are designed to provide reasonable protection against harmful 888.STEELCASE (888.783.3522)
  • Page 2: Table Of Contents

    Table of Contents ® Title page................1 Personal table: lay P.E.T. in position.........38 Table of contents..............2 Personal table: attach cantilever........39 Important safety instructions..........3 Personal table: use set screws to level......40 Power source/Glides/Drawer removal........5 Attach power box to cantilever..........41 Remove weight cover panels..........6 Collab table: subtop to cantilever........42 Ganging Light Seal...............7 Personal table: subtop to cantilever........43...
  • Page 3: Important Safety Instructions

    4. Never operate this table if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. If the cord is damaged, have it replaced by a Steelcase dealer.
  • Page 4 Nunca use esta mesa si tiene un cable o enchufe dañado, si no está funcionando correctamente, si se ha caído o dañado, o si se le ha dejado caer en el agua. Si el cable está dañado,...
  • Page 5: Power Source/Glides/Drawer Removal

    ® IMPORTANT: If installing Wall Hanging application, Screw in Glides Until Stop reference pages 67 - 71 for installation steps. Locate Power Source If Drawers are Present, Remove Them Page 5 of 71 1317809001 Rev A...
  • Page 6: Remove Weight Cover Panels

    Desk Foundation building. Verify correct counterweight is installed Remove Weight Cover Panels when reconfiguring. See Assembly Directions www.steelcase.com Counterweight Top Plate Remove Top Plate to install counterweight 1154833001 rev A Page 6 of 71 1317809001 Rev A...
  • Page 7: Ganging Light Seal

    ® Ganging Light Seal Installation (If installing single low mass, skip to pg. 9) Determine Mounting Location NOTE: If drawer is in end location where ganging, use location “b” toward where drawer opens. Page 7 of 71 1317809001 Rev A...
  • Page 8: Ganging Brackets

    ® For Multiple Foundations: Attach 3 Ganging Brackets Top Bracket Side Bracket Side Bracket Page 8 of 71 1317809001 Rev A...
  • Page 9: Attach End Skins

    ® Attach End Skins to Foundation 2x each skin 2x each skin Page 9 of 71 1317809001 Rev A...
  • Page 10: Install Lower Column Stabilizing Bracket

    ® Column Lower-Bracket Locating Chart Worksurface Location Bracket Location RH - Parallel or 36” wide 10 & 12 LH - Perpendicular 13 & 14 LH - Parallel or 36” wide 3 & 5 RH - Perpendicular 1 & 2 Collab - Centered 7 &...
  • Page 11 ® M8x14 Install Lower Column Stabilizer Bracket NOTE: Power cable will route under where Lower Column Stabilizer Brackets are. SIDE VIEW Page 11 of 71 1317809001 Rev A...
  • Page 12: Cable Routing Overview

    ® Cable Routing Overview Page 12 of 71 1317809001 Rev A...
  • Page 13: Route Power

    ® NOTE: If located against wall, attach back skin to foundation. (reference page 23). Place Unit in Desired Location Route Power Through Bottom of Foundation Page 13 of 71 1317809001 Rev A...
  • Page 14: Power Bracket Installation

    ® NOTE: 2 outlets will hang off bracket. Power Bracket Installation NOTE: Check all wiring connections before securing power supply. NOTE: Secure power supply with zip tie or drill 7/32 hole for strain relief (no specific hole location necessary). NOTE: Secure power supply with strain relief bracket or zip tie.
  • Page 15: Remove Column Lid And Lower Shroud

    ® M8x8 Remove Column Lid and Lower Shroud Page 15 of 71 1317809001 Rev A...
  • Page 16: Run Wires Through Column

    ® NOTE: If routing data, do so at this point in the installation. NOTE: Plug cable into Power Adapter and Motor located in column base. NOTE: Adapter will rest on the cantilever when installation is finished. Run Wires Through Column Power Unit Zip Tie in Place Page 16 of 71...
  • Page 17: Rout Power Through Column And Carrier

    ® Pull Through Foundation and Route Power Cord Up Next to Inlet Power Cord Through Column and Carrier Power Unit Page 17 of 71 1317809001 Rev A...
  • Page 18: Install Column Wire Cover

    ® Install Column Wire Cover Page 18 of 71 1317809001 Rev A...
  • Page 19: Level And Add Counterweights

    Remove Top Plate to install counterweight NOTE: If installing Floor Mount, skip 1154833001 rev A to page 21. NOTE: Reference Spec Guide for application rules (Section: “Mackinac Guidelines”). NOTE: Remove slides on only 54” Foundation. Page 19 of 71 1317809001 Rev A...
  • Page 20 ® TOPVIEW Heavy Duty Counterweight Package: Additional 14 counterweights behind column/centered (29 total) Level and Add Counterweights Options: Counterweights Counterweights NOTE: Do not apply counterweight cover on bay where column is to be installed for Heavy Duty. Page 20 of 71 Counterweights 1317809001 Rev A...
  • Page 21: Install Foundation To Floor

    Building construction varies greatly. The SEOR (Structural Engineer of Record) is responsible for the design of building walls and floors which Mackinac products are attached to and must verify the adequacy of the mounting hardware, even if provided by Steelcase.
  • Page 22: Reinstall Counterweight Coverplates

    ® Reinstall Counterweight Coverplates NOTE: Do not apply counterweight cover on bay where column is to be installed for Heavy Duty. Page 22 of 71 1317809001 Rev A...
  • Page 23: Attach Remaining Outerskin

    ® NOTE: Ensure the hooks engage completely in slots located on the lower mass. Attach Remaining Outer Skin Page 23 of 71 1317809001 Rev A...
  • Page 24: Install Touch Latch

    ® Install Touch Latch NOTE: Twist to calibrate TIP: Exposed plunger head faces the front of drawer, and ribs face inside of cabinet. Page 24 of 71 1317809001 Rev A...
  • Page 25: Attach Drawer

    ® Attach Drawer Page 25 of 71 1317809001 Rev A...
  • Page 26: Install Drawer Lock

    ® NOTE: Ensure that the circular lock indicator and the lock arm are both facing up when installing. lock arm Install Drawer Lock lock indicator Page 26 of 71 1317809001 Rev A...
  • Page 27: Plastic Lock Plug Removal/Lock Cylinder Installation

    ® Removal of Plastic Lock Plug and Installation of Lock Cylinder TURN 90 or 1:30 3:00 Page 27 of 71 1317809001 Rev A...
  • Page 28: Front Removal Of Lock Cylinder

    ® Front Removal of Lock Cylinder REMOVAL TOOL TOOL RK-XF TOOL RK-FR REMOVAL TOOL Page 28 of 71 1317809001 Rev A...
  • Page 29: Attach Drawer Panel

    ® Attach Drawer Panel Page 29 of 71 1317809001 Rev A...
  • Page 30: Level Foundation/Center Column

    ® Center Column in Final Location Verify that Foundation is Level Page 30 of 71 1317809001 Rev A...
  • Page 31: Install Upper Column Stabilizer Bracket

    ® Install Upper Column Stabilizer Bracket to Foundation M6x20 Page 31 of 71 1317809001 Rev A...
  • Page 32 ® M8x10 Attach Upper Stabilizing Bracket to Column M8x14 Page 32 of 71 1317809001 Rev A...
  • Page 33: Attach Shroud To Column

    ® M8x8 Attach Shroud to Column NOTE: Be careful not to scratch column when sliding into place. Page 33 of 71 1317809001 Rev A...
  • Page 34: Attach Column Lid

    ® NOTE: If installing Tower onto Foundation, skip to page 53. Attach Column Lid Page 34 of 71 1317809001 Rev A...
  • Page 35: Collab Table: Lay P.e.t. In Position

    ® Collab Table: Lay P.E.T. into Position Page 35 of 71 1317809001 Rev A...
  • Page 36: Collab Table: Attach Cantilever

    ® Collab Table: Attach Cantilever Locate screws Page 36 of 71 1317809001 Rev A...
  • Page 37: Collab Table: Use Set Screws To Level

    ® Fully tighten all M8 screws Adjust set screws to level Hand tighten M8 screws Collab Table: Use Set Screws to Level NOTE: Level the cantilever slightly high on far end. Page 37 of 71 1317809001 Rev A...
  • Page 38: Personal Table: Lay P.e.t. In Position

    ® Personal Table: Lay P.E.T. into Position Page 38 of 71 1317809001 Rev A...
  • Page 39: Personal Table: Attach Cantilever

    ® Personal Table: Attach Cantilever Locate screws Page 39 of 71 1317809001 Rev A...
  • Page 40: Personal Table: Use Set Screws To Level

    ® Fully tighten all M8 screws Adjust set screws to level Hand tighten M8 screws Personal Table: Use Set Screws to Level NOTE: Level the cantilever Page 40 of 71 slightly high on far end. 1317809001 Rev A...
  • Page 41: Attach Power Box To Cantilever

    ® NOTE: See page 12 for cable routing Attach Power Box to Cantilever Page 41 of 71 1317809001 Rev A...
  • Page 42: Collab Table: Subtop To Cantilever

    M8x10 ® Attach Subtop to Cantilever (Collab Table) M8x8 Page 42 of 71 1317809001 Rev A...
  • Page 43: Personal Table: Subtop To Cantilever

    ® Attach Subtop to Cantilever (Personal Table) M6x6 NOTE: If Worksurface is glass / corian, this will come installed to top. Install these screws first. Page 43 of 71 1317809001 Rev A...
  • Page 44: Perpendicular: Modesty Panel Bracket

    ® Attach Modestly Panel Bracket (Perpendicular Table) Page 44 of 71 1317809001 Rev A...
  • Page 45: Perpendicular: Modesty Panel

    ® Attach Modestly Panel (Perpendicular Table) Page 45 of 71 1317809001 Rev A...
  • Page 46: Attach Worksurface To Cantilever

    ® NOTE: Use pilot holes to attach. Attach Worksurface to Cantilever WORKSURFACE FOUNDATION 1” Start attachment with the 4 screws boxed. Page 46 of 71 1317809001 Rev A...
  • Page 47: Attach Power Grommets

    ® Attach Power Grommets Page 47 of 71 1317809001 Rev A...
  • Page 48: Attach C-Clamp Brackets

    ® Attach C - Clamp Brackets NOTE: Rock c-clamp into place. Page 48 of 71 1317809001 Rev A...
  • Page 49: Secure Power Box In Cantilever

    ® NOTE: Zip tie all wires to the Cantilever, they cannot be hanging down. Secure Power Box inside Cantilever NOTE: Secure power box with screws into wood, or zip tie to understructure. Page 49 of 71 1317809001 Rev A...
  • Page 50: Attach Up/Down Lever To Worksurface And Power

    ® WOOD TABLE Attach Up/Down Lever to Worksurface and Power GLASS/CORIAN TABLE Page 50 of 71 1317809001 Rev A...
  • Page 51: Attach P.e.t. To Underside Of Worksurface

    ® NOTE: Bend P.E.T. to slip brackets into final position. Attach P.E.T. to Underside of Worksurface Page 51 of 71 1317809001 Rev A...
  • Page 52: Attach Final Coverplate

    ® Attach Final Cover Plate to P.E.T. (Parallel & Perpendicular) Page 52 of 71 1317809001 Rev A...
  • Page 53: Tower And Shroud Installation

    ® Tower and Shroud Installation Page 53 of 71 1317809001 Rev A...
  • Page 54: Attach Z Brackets To Bottom Weldment

    ® Bottom View Assemble Z Brackets to Bottom Weldment 12mm Page 54 of 71 1317809001 Rev A...
  • Page 55: Attach Rh Upright Weldment

    ® Attach RH Upright Weldment to Bottom Weldment SIDE VIEW Page 55 of 71 1317809001 Rev A...
  • Page 56: Attach Lh Upright Weldment

    ® Attach LH Upright Weldment to Bottom Weldment Page 56 of 71 1317809001 Rev A...
  • Page 57: Attach Upper Weldment

    ® Attach Upper Weldment to both RH & LH Uprights Page 57 of 71 1317809001 Rev A...
  • Page 58: Attach Center Column(S)

    ® Attach Center Column(s) Page 58 of 71 1317809001 Rev A...
  • Page 59: Attach Shelves To Column

    ® Attach Shelves to Column Page 59 of 71 1317809001 Rev A...
  • Page 60: Attach Tower To Foundation

    ® 10-32 Attach Tower to Foundation Page 60 of 71 1317809001 Rev A...
  • Page 61: Place Topskin On Foundation

    ® Place Top Skin onto Foundation Place supplied felt pad in space between foundation and top skin. Page 61 of 71 1317809001 Rev A...
  • Page 62: Attach Shelf Light

    ® NOTE: Light is attached magnetically. Attach Shelf Light NOTE: Manage cords with tape (vertical pillars preferable). Page 62 of 71 1317809001 Rev A...
  • Page 63: Half Shroud Installation

    ® Shroud Bracket Installation Choose shroud location and attach bracket(s). Half Shroud Installation TOP VIEW NOTE: Bend until complient NOTE: Slide shroud flange into bracket. Page 63 of 71 1317809001 Rev A...
  • Page 64: Full Shroud Installation

    ® Full Shroud Installation TOP VIEW NOTE: Bend until complient NOTE: Slide shroud flanges into bracket. Page 64 of 71 1317809001 Rev A...
  • Page 65: Monitor Installation

    ® NOTE: Install monitor mounts and monitor per vendor instructions. Monitor Installation 13mm Burn holes from inside screen (13mm from up from top of flange) Page 65 of 71 1317809001 Rev A...
  • Page 66: Attach Shroud Cover

    ® Attach Shroud Cover Page 66 of 71 1317809001 Rev A...
  • Page 67: Wall Hanging Application

    Building construction varies greatly. The SEOR (Structural Engineer of Record) is responsible for the design of building walls and floors which Mackinac products are attached to and must verify the adequacy of the mounting hardware, even if provided by Steelcase.
  • Page 68: Mounting Plate / Wall Mount

    WARNING ® CRUSH HAZARD. Failure to properly secure Mackinac products could result in personal injury. Read entire Assembly Direction for your product mounting configuration. Verify all walls meet minimum required construction guidelines before Mounting Plate / Wall Mount beginning installation. Install ALL fasteners required. Obtain assembly directions from a Steelcase dealer or call 1-888-783-3522.
  • Page 69: Center Of Gravity Location And Total Weight

    ® Perpendicular Application Center of Gravity Location Total Weight: and Total Weight 1043.81 lbs *Worst Case Collaborative, Parallel, and Perpendicular Condition* (to be used by the Structural Engineer of Record) Maximum Load Value and Load Location to Determine the Correct Wall or Floor Fasteners for NON-SEISMIC APPLICATIONS only *For Seismic Applications consult the SEOR (Structural Engineer of Record)*...
  • Page 70: Attach Column To Wall Mount

    ® M8x10 Attach Column to Wall Mount Page 70 of 71 1317809001 Rev A...
  • Page 71: Attach Shroud To Column

    ® IMPORTANT: After this page, reference pages 33 - 52 for next installation steps. Attach Shroud to Column NOTE: Be careful not to scratch column when sliding into place. M8x8 TIP: Base trim needs to be removed to allow wall plate to set flush against wall.

Table of Contents