Operation
4.4. The RUN Screen
The Fyrite
INSIGHT
Plus test data is located in the Run screen. By pressing
the RUN/HOLD button, you should hear the pump running and see the word
RUN at the upper-left hand corner of the display.
continuously measuring and calculating the data that is shown in the Run
screen.
Press the RUN/HOLD button again. The pump should stop running and the
word HOLD should be shown at the upper-left hand corner of the display. The
instrument now shows the last measured and calculated data taken before the
instrument was placed in HOLD.
Use the UP () and DOWN () arrow buttons to scroll through the complete
list of measured and calculated values when the instrument is running or in the
HOLD mode.
Combustion Test Parameters
Oxygen
Carbon Monoxide
Excess Air
Efficiency Using Higher Heating Value
Carbon Dioxide
Setting for Maximum Carbon Dioxide in Flue Gas
Stack Temperature
Ambient Air Temperature
Stack Loss
Efficiency Using Lower Heating Value
Carbon Monoxide/Carbon Dioxide Ratio
CO content referenced to an Oxygen percentage n
Average of 3 Manually Entered Smoke Numbers
Presence of Oil Derivatives (Manually Entered)
Boiler Temperature (Manually Entered)
66
GlobalTestSupply
www.
Fyrite
INSIGHT
Plus Manual
The instrument is
NA
Siegert
O₂
O₂
CO
CO
EA
Lambda
Eff
Eff
CO₂
CO₂
CO₂ Max
T-STK
T-STK
T-AIR
T-AIR
qA
Eta
CO/CO₂
CO(n)
CO(n)
AVG SMOKE
OIL DERIVE
BOILER TEMP