Sign In
Upload
Manuals
Brands
Bacharach Manuals
Measuring Instruments
Fyrite INSIGHT PLUS
User Manuals: Bacharach Fyrite INSIGHT PLUS Analyzer
Manuals and User Guides for Bacharach Fyrite INSIGHT PLUS Analyzer. We have
2
Bacharach Fyrite INSIGHT PLUS Analyzer manuals available for free PDF download: Instruction Manual
Bacharach Fyrite INSIGHT PLUS Instruction Manual (112 pages)
Combustion Gas Analyzer
Brand:
Bacharach
| Category:
Measuring Instruments
| Size: 4 MB
Table of Contents
Instruction Manual
1
Table of Contents
4
Overview
7
Conventions
7
Introduction
7
Safety
7
Section 1. Overview
7
North American (NA) Vs. Siegert (S) Combustion Equations
9
Product Overview
9
Components
11
Features
13
Combustion Test Process Overview
15
Fyrite INSIGHT Plus Sales Combinations
16
Specifications
17
Setup
21
Connecting the Probe and Thermocouple
21
Section 2. Setup
21
Front Panel Buttons
22
Power Options
24
Turning the Fyrite INSIGHT Plus On/Off
25
Configuration
27
Menu Structure Overview
27
Section 3. Configuration
27
The Warm-Up Sequence
27
Main Menu
28
Select Fuel Menu
30
Pressure Menu
32
Temperature Menu
32
Leak Test Menu (Siegert Only)
33
Ambient CO Menu (Siegert Only)
34
Memory Options Menu
36
Setup Menu
38
Calibration Menu
57
Diagnostics Menu
58
Status Menu
61
Operation
62
Prerequisites
62
Sampling Point Examples
62
Section 4. Operation
62
Fyrite INSIGHT Plus Manual
65
Combustion Testing Process
65
The RUN Screen
67
Making a Draft or Pressure Measurement
69
Printing Using the Optional Irda Printer
70
Graphics Screens
73
Overview
73
Graphical Line Graph Trend Screen
74
Bar Graph Screen
75
Stack Temperature Hot Spot Screen
78
Taking Ambient CO Measurements (Siegert Only)
78
PC Interface and Fyrite User Software
79
Calibration and Maintenance
80
Serviceability
80
Cleaning the Probe
80
Equipment Required
81
Procedure
81
Water Trap and Filter Replacement
82
And/Or CO Sensor Replacement
83
Accessing the Sensors
83
Material Required (as Needed)
83
Sensor Replacement Procedure
83
CO Sensor Replacement Procedure
84
B-SMART CO Sensor Replacement
86
Pressure Sensor Calibration
87
Materials Required
87
Procedure
87
T-Stack Calibration
89
Materials Required
89
T-Stack Calibration Procedure
89
T-Air Calibration
91
Materials Required
91
T-Air Calibration Procedure
92
CO Sensor Calibration
94
Materials Required
94
CO Manual Zero Procedure
94
CO Sensor Span Procedure
95
T-Ref Sensor Calibration
96
Troubleshooting
98
Section 6. Troubleshooting
98
Error and Warning Messages
98
Replacement Parts
100
Accessories
101
Instrument Identification
102
Service Centers
102
CE Declaration of Conformity
103
Index
105
Advertisement
Bacharach Fyrite INSIGHT PLUS Instruction Manual (116 pages)
Combustion gas analyzer
Brand:
Bacharach
| Category:
Measuring Instruments
| Size: 8 MB
Table of Contents
Table of Contents
4
Overview
7
Introduction
7
Conventions
7
Safety
7
Product Overview
9
North American (NA) Vs. Siegert (S) Combustion Equations
9
Components
11
Features
13
Combustion Test Process Overview
15
Fyrite INSIGHT Plus Sales Combinations
16
Specifications
17
Setup
21
Connecting the Probe and Thermocouple
21
Front Panel Buttons
22
Power Options
24
Turning the Fyrite INSIGHT Plus On/Off
25
Configuration
27
Menu Structure Overview
27
The Warm-Up Sequence
27
Main Menu
28
Select Fuel Menu
30
Pressure Menu
32
Temperature Menu
32
Tune-Rite Option (North American Only)
33
Leak Test Menu (Siegert Only)
33
Ambient CO Menu (Siegert Only)
35
Memory Options Menu
36
Setup Menu
38
Calibration Menu
61
Diagnostics Menu
62
Status Menu
65
Fyrite INSIGHT Plus Manual
67
Operation
67
Prerequisites
67
Sampling Point Examples
67
Combustion Testing Process
70
The RUN Screen
72
Making a Draft or Pressure Measurement
74
Printing Using the Optional Irda Printer
75
Graphics Screens
78
Overview
78
Graphical Line Graph Trend Screen
79
Bar Graph Screen
80
Stack Temperature Hot Spot Screen
83
Taking Ambient CO Measurements (Siegert Only)
83
PC Interface and Fyrite User Software
84
Calibration and Maintenance
85
Serviceability
85
Cleaning the Probe
85
Equipment Required
86
Procedure
86
Water Trap and Filter Replacement
87
And/Or CO Sensor Replacement
88
Accessing the Sensors
88
Material Required (as Needed)
88
Sensor Replacement Procedure
88
CO Sensor Replacement Procedure
89
B-SMART CO Sensor Replacement
91
Pressure Sensor Calibration
92
Materials Required
92
Procedure
92
T-Stack Calibration
94
Materials Required
94
T-Stack Calibration Procedure
94
T-Air Calibration
96
Materials Required
96
T-Air Calibration Procedure
97
CO Sensor Calibration
99
Materials Required
99
CO Manual Zero Procedure
99
CO Sensor Span Procedure
100
T-Ref Sensor Calibration
101
Troubleshooting
102
Error and Warning Messages
102
Replacement Parts
104
Accessories
105
Instrument Identification
106
Service Centers
106
CE Declaration of Conformity
107
Index
109
Advertisement
Related Products
Bacharach Fyrite INTECH
Bacharach FM3600
Bacharach FM3700
Bacharach High Flow Sampler
Bacharach Fyrite INSIGHT
Bacharach Fyrite Pro
Bacharach Fyrite
Bacharach FYRITE CO2
Bacharach FM3600 R-S
Bacharach FieldServer ProtoNode
Bacharach Categories
Measuring Instruments
Test Equipment
Gas Detectors
Security Sensors
Controller
More Bacharach Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL