Table 26. Construction Situation Checklist - Samsung 310 5G CPE Installation Manual

Outdoor unit
Hide thumbs Also See for 310 5G CPE:
Table of Contents

Advertisement

On-site Inspection and Inspection Checklist
The on-site inspection is to perform inspection visually or using instruments for
each specification, standard, and installation status, based on the inspection
checklist at the site where the system is installed.
The inspector must record the results onto the inspection checklist during or after
the field inspection.
Sharing Inspection Results and Taking Corrective Actions
The inspector must share the inspection results (inspection checklist and corrective
actions) with an installation operator. The installation operator must take the
corrective actions, if necessary, after reviewing the requirements.
Checking the Results of Corrective Actions
The inspector must check if the corrective actions are properly taken. If they are
not sufficient, the inspector must ask the installation operator to take the corrective
actions again.
Sharing the Results of Corrective Actions and Preparing Preventive Plan
After the corrective actions are all completed, the inspector must share the results
with the installation operator and relevant departments. The inspector must prepare
a preventive plan to prevent the same or similar problems from re-occurring.
Construction Situation Checklist
The table below provides the checklist to check the installation of the CPE
Outdoor and other devices.

Table 26. Construction Situation Checklist

Category
Check Items
Installing
Appearance of equipment
Equipment
and mechanical parts
Placement of equipment
and mechanical parts
Leveling condition of
equipment and
mechanical parts
Validity of status and
specifications of fastening
bolt, nut, and washer
Grounding
Installation of ground bar
Cable specification
5G CPE Outdoor Installation Manual v1.0
Copyright © 2018, All Rights Reserved
Criteria
Equipment damage such as dent,
scratch, and crack
Maintenance and horizontal/vertical
placement
Horizontal/vertical status
Checking fasteners omission
Compliance with assembly order of
fasteners
Compliance with fastening torque value
Checking the separation of
communication/power/lightning
grounding
Checking the specification
Confidential
Chapter 4 Inspect the Installation
Result
Pass
Fail
53