Grounding

Grounding is the process of operating an electronic system such as a power supply
system, communication system, and control system, stably without damage from
lightning, transient-current, transient-voltage, and electric noise. Grounding also
helps in preventing injury from electric shock.
Ground equipment minimizes the electrical potential of the electronic device to
that of the ground, which is zero electrical potential. This prevents electrification
of the electronic device.
Connect the ground cable first. In cabling, the connection of cables without the
connection to the ground cable may cause damage of the equipment or bodily
injury to personnel.
The purposes of the ground construction are as follows:

Connecting Ground Cable

When connecting the ground cables, connect the ground cable first before
installing the system to prevent errors.
1

Table 17. Parts and Tools for Connecting Ground Cable

Category
Description
Installation Section
MGB-CPE Outdoor Ground Terminal
Cable
14 AWG × 1C
Bending Radius
8 × OD
Ф 0.4 in. (10 mm)/Clear/2 in. (50 mm)
Heat Shrink Tube
(Spec/Color/Length)
Pressure Terminal
MGB
CPE
Outdoor
5G CPE Outdoor Installation Manual v1.0
Copyright © 2018, All Rights Reserved.
To prevent human life and the system from over-current, over-voltage, and
lightning
To provide a discharge path for surge voltage generated by lightning and
power switch
To protect the system from static electricity
To eliminate or minimize the high-frequency potential in the system housing
To provide a conductor for the balance and stability of high-frequency current
To stabilize the potential of the circuit against the ground
To connect a ground cable
Ensure that the items mentioned in the table below are available.
Checking MGB specifications per site and preparing connecting parts
14 AWG, 2 Hole, Hole diameter: 1/4 in. (6.4 mm), Hole spacing: 0.63 in.
(16 mm)