Honeywell Midas User Manual page 83

Hide thumbs Also See for Midas:
Table of Contents

Advertisement

9 Pyrolyzer Module Options
Two Midas Pyrolyzer modules are available to
detect specific gases (consult the Midas data
sheets for an updated list of detectable species).
The pyrolyzer module option is installed under
the Midas gas detector. An air sample is drawn
through the pyrolyzer and the target fluorinated
compounds are converted into hydrogen
fluoride (HF) gas by means of pyrolysis at a
high temperature which is optimized for each
gas family. The residual HF is then measured
by the appropriate sensor cartridge and the
concentration is calculated from this result. This
concentration is then displayed in actual ppm on
the Midas' LCD display.
The standard Midas pyrolyzer unit (P/N MIDAS-
T-NP1) detects nitrogen triflouride (NF
Perfluoro compounds (CH
The pyrolyzer unit for NF
utilize a Freon end-of-line filter (P/N 1830-0027).
The filter is filled with charcoal to remove Freon
Diagram 9-1. Midas gas detector with pyrolyzer modules (left to right: MIDAS-T-0P3, MIDAS-T-00P, MIDAS-T-HTP, and MIDAS-T-NP1).
Ventilated Top Cover
) and
3
F, C
F
, C
F
, CH
F
).
3
4
6
5
8
2
2
, CH
F and CH
F
can
3
2
3
2
Midas
and other similar compounds from the sample gas
before it is "cracked" in the pyrolyzer.
Diagram 9-1 illustrates the various pyrolyzer
configurations. This table shows that gases
which can be detected by the Midas Pyrolyzer
module.
Detectable Gases
Cartridge Part No.
MIDAS-E-XHF,
MIDAS-S-XHF
MIDAS-E-XCF,
MIDAS-S-XCF
Note that the pyrolyzer module is ideally suited for
leak detection rather than analytical detection of
very low trace amounts of PFC compounds.
Midas Gas Detector
Midas Pyrolyzers
9-2
Gas Detector
®
Gas
Gas ID
NF
01
3
CH
F
02
3
C
F
01
4
6
C
F
02
5
8
CH
F
03
2
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents