8.1 Sensor Cartridge Replacement
Honeywell Analytics recommends that the sensor
cartridge be replaced without power to the Midas
unit. If fitting a sensor cartridge to a unit that is
powered, please refer to
detector's outputs.
8.1.1 Sensor Cartridge Fitting/Replace-
ment
1. Unscrew the thumbscrew located on the
front panel and remove the cover by pulling
it forwards off the main chassis (see Diagram
27).
2. Ensure the power switch on the terminal
module is in the off position.
3. Remove the old sensor cartridge from the unit
(if fitted) by unclipping the two sensor cartridge
locking
tabs located either side of the sensor cartridge
and using them to firmly pull the sensor
cartridge out
(see diagram 23).
4. Fit the new sensor cartridge by aligning the
pins at the top of the sensor cartridge with the
socket in the sensor cartridge chamber.
5. Carefully push the sensor cartridge into the
sensor cartridge chamber until fully home and
lock in place using the tabs either side of the
sensor cartridge (see diagram 24).
6. Switch the power switch on the terminal
module to the 'on' position.
7. Refit the detector's cover by aligning the
slots either side with the locating tabs on the
mounting bracket assembly and pushing the
cover horizontally until home. Tighten the
thumbscrew located on the front panel (see
Section 7.4.3
to inhibit the
Midas
diagram 25).
8. Confirm that the LCD messages "LOAd" and
"WArm" are replaced by a zero concentration
®
display. Confirm that the yellow fault LED is
off.
Note
If replacing a sensor cartridge with a different
gas type sensor cartridge the display will
scroll the message 'ChAngE gAS?' If you are
changing the sensor cartridge gas type press
'3' to accept. If not, fit the correct sensor
cartridge. The pass code (if set) must be
entered to change sensor cartridge gas type.
To set the correct gas for a multi gas type
sensor cartridge refer to
Diagram 8-1. Removing detector cover
REMOVING COVER
chassis
mounting
bracket
Diagram 8-2. Removing sensor cartridge
8-3
Gas Detector
®
Section
7.2.2.
mid as
Gas Sen
cover
sor Car
tridg e
NIT RO
GE N TR
IFL UO
NF 3
RID E
PN : MID
AS -S-
SN : 023
HF X
Us e by
445 667
0
: 07- 09-
200 6
sensor
mi das
Gas Sen
sor Car
trid ge
NIT RO
GE N TR
IFL UO
NF 3
RID E
PN : MID
AS -S-
SN : 023
HF X
Us e by
445 667
0
: 07- 09-
zell weg
200 6
er ana
lytic s
loosen

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents