APPENDIX 1 - Energy Saving Presets

1
Fan Control Mode
2
1st Stage Differential Heat
3
2nd Stage Differential Heat
4
1st Stage Differential Cool
5
Guest Occupancy Threshold
6
Night Occupancy Threshold
7
Force 2nd Stage Heating After
8
Night Occupancy Start
9
Night Occupancy End
10
Recovery Time
11
Recovery Temperature Heat
12
Setback Delay - Heat
13
Minimum Setback Temperature
14
Setback Delay - Cool
15
Maximum Setback Temperature
16
Recovery Temperature Cool
17
Minimum Set point
18
Maximum Set point
19
Temperature Control Mode
20
Auto Changeover Set Point
21
Auto Restore
21
Setback Set Points
22
Automatic Humidity Control
23
Temperature Calibration
www.myamtex.com
48
Level
Level
Level
Level
Level
0
1
2
3
4
AUTO AUTO AUTO AUTO AUTO AUTO
0.5
0.5
0.5
0.5
0.5
1
1
1
2
2
0.5
0.5
0.5
0.5
0.5
0
5
5
5
5
1
1
1
1
1
30
30
30
30
30
18
19
20
21
22
12
11
10
9
8
0
15
20
25
30
70
69
68
67
66
0
30
25
20
15
67
66
65
64
63
0
30
25
20
15
72
74
76
78
80
71
72
73
74
75
64
64
65
66
67
82
82
80
78
76
AUTO AUTO AUTO AUTO AUTO AUTO
1
1
1
1
1
OFF
ON
ON
ON
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
0
0
0
0
0
800-650-3360

APPENDIX 2 - Glossary

"Automatic Fan Control Mode" - fan runs only
when there is a demand for heating or cooling;
Level
5
"Manual Fan Control Mode" - guest can select
between automatic or continuous fan operation;
"Minimum Set point" - minimum temperature
that a guest can request;
0.5
"Maximum Set point" - maximum temperature
that a guest can request;
2
"Auto Changeover Set Point Offset" - the
0.5
difference between the guest-selected set point
and the heat and cool changeover temperatures;
5
"1st Stage Differential - Heat" - the temperature
that the thermostat has to sense between the
1
automatic changeover temperature for heat and
the room temperature before a call for the 1st
30
stage heating is initiated;
23
"2nd Stage Differential - Heat" - difference
between 1st stage heating temperature and
7
room temperature before the 2nd stage heating
is initiated;
0
"1st Stage Differential - Cool" - the temperature
that the thermostat has to sense between the
65
automatic changeover temperature for cool and
the room temperature before a call for the 1st
10
stage cooling is initiated;
62
"Forced 2nd Stage Heating" - number of minutes
1st stage heating will run before 2nd stage
10
heating is automatically initiated if the guest set
point is not reached and the 2nd stage heating is
82
not initiated through differential settings
"Temperature Recovery Time" - the maximum
76
period of time allowed for restoring the
"Recovery Temperature";
68
"Recovery Temperature" - the room temperature
74
that needs to be restored within the
"Temperature Recovery Time";
"Maximum Setback Temperature" - the highest
room temperature allowed when thermostat is
1
in the setback mode;
ON
"Minimum Setback Temperature" - the lowest
room temperature allowed when thermostat is
ON
in the setback mode;
ON
"Temperature Setback Delay" - the length of
time for which the room that is in the guest
0
occupancy mode needs to be unoccupied before
the temperature setback is initiated;
www.myamtex.com
"Incidental Occupancy Threshold" - the minimum
period of time (in minutes) for which occupancy
needs to be detected in order to enter the "Guest
Occupancy" mode;
"Night Occupancy Threshold" - the minimum
period of time during the "Night Occupancy"
period for which occupancy needs to be detected
in order to enter the "Night Occupancy" mode;
"Night Occupancy Period" - The period of
time during the day during which the "Night
Occupancy" mode can be activated if occupancy
longer than the "Night Occupancy Threshold"
is detected;
"Auto Restore On" - thermostat will restore the
most recent guest settings when new occupancy
is detected;
"Auto Restore Off" - thermostat will NOT restore
the most recent guest and will remain turned off
settings when new occupancy is detected;
"Setback Set points On" - thermostat will
maintain setback temperatures when room is
unoccupied;
"Setback Set points Off" - thermostat will NOT
maintain setback temperatures when room is
unoccupied;
"Incidental Occupancy" - occupancy shorter than
the "Incidental Occupancy Threshold";
"Guest Occupancy" - occupancy longer than the
"Incidental Occupancy Threshold";
"Temperature Setback" - thermostat maintains
setback temperatures and not the guest set
point temperature in order to save energy;
"Night Occupancy Mode" - thermostat status
during which setback mode is disabled if
occupancy longer than "Night Occupancy
Threshold" is detected within the "Nigh
Occupancy" period;
"Automatic Temperature Changeover" -
thermostat automatically activates heating
or cooling to maintain the desired room
temperature;
"External Thermostat" (Class 2) mode - PTAC unit
setting allowing it to be controlled by a remote
thermostat;
800-650-3360
49