52
Chapter 4
INT
R/W
CHAR
R/W
CHAR
R/W
CHAR
R/W
CHAR
R/W
BOOL
R/W
BOOL
R/W
INT (hex) R/W
Function
Function
BOOL
R/W
BOOL
R/W
INT
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
BOOL
R/W
Function
BOOL
R/W
BOOL
R/W
BOOL
R/W
INT
R/W
ASCII Command Protocol
Verify or Set the trailing character count
(0 to 3) u
Verify or set end of line termination character
( A - Z, 0 - 9, a - z or ASCII \0x00 ....\0x0D)
Verify or set separating character between the facil-
ity code and ID data( A - Z, 0 - 9, a - z or ASCII \0x00
....\0x0D) Ex: 123 ; 456789
1st character sent when card is removed
( A - Z, 0 - 9, a - z or ASCII \0x00 ....\0x0D)
2nd character sent when card is removed
( A - Z, 0 - 9, a - z or ASCII \0x00 ....\0x0D)
IF True, enable echo of user input and use of backspace
key
IF True, enable RF IDeas command prompt
Verify or set the logical unique identifier as 16 bit INT
(0x0000..0xFFFF)
Read the device part number
Read firmware version (major . minor . variant)
IF True, use 64 bit math on ID data
IF True, use 64 bit math on facility code data
Verify or set Length of facility code output
(up to 25 digits)
IF True, enable facility code output as hex
Enable output of facility code
Set to True to separate ID and FAC. False processes ID
and FAC together.
IF True, hex ID data is output in lowercase
Verify or Set ID data length (0 to 25 digits) Note: If
value is shorter than actual Id length the left most
significant digits will be truncated
IF True, enable ID data output as hex
View menu of commands, summary of output types
and variable options
Beeper output control True=beep, False=silent
Continuous read mode True=continuous
output, False=single output of credential data
IF True, enable Quiet mode. (IE: Credential data is not
displayed) Note: data can still be retrieved using
function rfid:qid.
LED output control 0=off, 1=red, 2=green,
(Immediate out w\o write)
255=Automatic control by reader (requires write to
flash) red on standby, green when credential is read
3=Amber

Hide quick links: