Table Of Contents - IntesisBox ME-AC-KNX-1i User Manual

Table of Contents

Advertisement

KNX - Mitsubishi Electric A.C.
®
IntesisBox
INDEX
1.
Presentation .................................................................................................... 6
2.
Connection ...................................................................................................... 7
3.
Configuration and setup .................................................................................... 8
4.
ETS Parameters ............................................................................................... 9
4.1
General dialog ............................................................................................ 10
4.1.1
Send READs for Control_ objects on bus recovery ..................................... 10
4.1.2
Scene to load on bus recovery / startup ................................................... 10
4.1.3
Disallow control from remote controller .................................................... 10
4.1.4
4.1.5
4.1.6
4.1.7
4.2
Mode Configuration dialog ............................................................................ 13
4.2.1
Indoor unit has FAN mode ...................................................................... 13
4.2.2
Enable use of Heat / Cool bit-type obj ...................................................... 13
4.2.3
Enable PID-Compat. Scaling Mode Objects ............................................... 14
4.2.4
Enable use of + / - object for Mode ......................................................... 15
4.2.5
Enable use of bit-type Mode objects (for control) ...................................... 15
4.2.6
Enable use of bit-type Mode objects (for status)........................................ 16
4.2.7
Enable use of Text object for Mode .......................................................... 16
4.2.8
Enable use of Legacy_ object for Mode .................................................... 16
4.3
Special Modes Configuration dialog ................................................................ 17
4.3.1
Enable use of POWER mode .................................................................... 17
4.3.2
Enable use of ECONOMY mode ................................................................ 18
4.3.3
Enable use of ADDITIONAL HEATING mode .............................................. 19
4.3.4
Enable use of ADDITIONAL COOLING mode .............................................. 20
4.4
Fan Speed Configuration dialog ..................................................................... 21
4.4.1
Fan is accessible in Indoor unit ............................................................... 21
4.4.2
Available fanspeeds in Indoor Unit ........................................................... 21
4.4.3
Indoor unit has AUTO fan speed .............................................................. 22
4.4.4
DPT object type for fanspeed .................................................................. 22
4.4.5
Enable use of +/- object for Fan Speed .................................................... 23
4.4.6
4.4.7
4.4.8
Enable use of bit-type Fan Speed objects (for Status) ................................ 25
4.4.9
Enable use of Text object for Fan Speed ................................................... 25
4.4.10
Enable use of Legacy_ object for Fan Speed ............................................. 26
4.5
Vanes Up-Down Configuration dialog ............................................................. 26
4.5.1
Indoor unit has U-D Vanes ..................................................................... 26
4.5.2
Available positions in Indoor Unit ............................................................ 27
4.5.3
Indoor unit has AUTO Vanes U-D ............................................................ 27
4.5.4
DPT object type for Vanes Up-Down ........................................................ 27
4.5.5
Enable use of +/- object for Vanes U-D .................................................... 28
4.5.6
Enable use of bit-type Vane U-D objects (for Control) ................................ 29
4.5.7
Enable use of bit-type Vane U-D objects (for Status) ................................. 30
4.5.8
4.5.9
4.5.10
Enable use of Text object for Vane U-D .................................................... 31
4.5.11
Enable use of Legacy_ object for Vanes ................................................... 32
4.6
Temperature Configuration dialog.................................................................. 32
4.6.1
4.6.2
4.6.3
Enable use of +/- object for Setpoint Temp .............................................. 33
This information is subject to change without notice
®
IntesisBox
is a registered trademark of Intesis Software SLU
User's manual r2.3 eng
URL
http://www.intesisbox.com
Email
info@intesisbox.com
tel
+34 938047134
4 / 63

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ME-AC-KNX-1i and is the answer not in the manual?

Table of Contents