C O N T E N T S General Information Limited Warranty (USA Only) Safety Guidelines Maintenance Guidelines Fixture Overview Lens and Gobo Holder Installation Fixture Installation System Menu DMX Channel Functions And Values Specifications Optional Accessories...
Power Cable Safety Cable NOTE: Lens Not Included Sold Separately CUSTOMER SUPPORT Contact ELATION Service for any product related service and support needs. Also visit forums.elationlighting.com with questions, comments or suggestions. ELATION SERVICE USA - Monday - Friday 8:00am to 4:30pm PST 323-582-3322 | Fax 323-832-9142 | support@elationlighting.com...
No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof. C. This warranty is void if the product serial number and/or labels are altered or removed;...
S A F E T Y G U I D E L I N E S This fixture is an extremely sophisticated piece of electronic equipment. To guarantee a smooth operation, it is important to follow all instructions and guidelines in this manual. The manufacturer of this device is not responsible for injury and/or damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual.
Regular inspections are recommended to insure proper function and extended life. There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer.
F I X T U R E O V E R V I E W Lens (not included) 10. 3pin DMX IN FOCUS 11. 3pin DMX OUT UP Button 12. 5pin DMX OUT DOWN Button 13. powerCON TRUE1 IN MODE/ESC Button 14.
F I X T U R E I N S T A L L A T I O N FLAMMABLE MATERIAL WARNING Keep fixture minimum 5.0 feet (1.5m) away from flammable materials and/or pyrotechnics. ELECTRICAL CONNECTIONS A qualified electrician should be used for all electrical connections and/or installations. USE CAUTION WHEN POWER LINKING OTHER MODEL FIXTURES AS THE POWER CONSUMPTION OF OTHER MODEL FIXTURES MAY EXCEED THE MAX POWER OUTPUT ON THIS FIXTURE.
Page 11
F I X T U R E I N S T A L L A T I O N CLAMP MOUNTING This fixture includes an adjustable mounting yoke and safety cable rigging point attached to the fixture (see the illustration below). When mounting this fixture to truss, be sure to secure an appropriately rated clamp (not included) to the yoke using an M10 screw, and attach a SAFETY CABLE to the fixture safety cable rigging point.
S Y S T E M M E N U The fixture includes an easy to navigate system menu. The control panel (see image below) located on the front of the fixture, provides access to the main system menu and is where all necessary system adjustments are made to the fixture.
Page 13
ELATION WW PROFILE HP S Y S T E M M E N U Supports Software Versions: ≥1.1.0 Features are subject to change without any prior written notice. OPTIONS / VALUES (Default Settings in MAIN MENU SUB MENU DESCRIPTION BOLD)
Page 14
Persnal - Stat Set - Addr DMX When ON, define the desired fixture DMX address via an external controller. NOTE: This process assumes the fixture DMX address is set to 001. If fixture DMX address is not at 001, you must adjust the channel numbers listed below accordingly in order for this feature to work. For example: if your fixture address is 010, then Channel 1 becomes Channel 10, Channel 2 becomes Channel 11, and Channel 3 becomes Channel 12.
Page 15
Persnal - Reset Default (011) ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THIS FUNCTION. NOTE: SAVED WHITE BALANCE IS ERASED AFTER A RESET IS PERFORMED. This function restores all fixture settings to the factory default settings. The password is 011 and must be entered each time a reset is performed. EditProg –...
Page 16
EDIT PROGRAM – Record Controller – Working With Built In Programs A Master unit can send up to 3 different data groups to the Slave units, i.e. a Master unit can start 3 different Slave units, which run 3 different programs. The Master unit sends the 3 program parts in a continuous loop.
Page 17
EDIT PROGRAM – Record Controller – Working With Built-In Program [continued] 3. Program Selection for Auto Pro Part • Select “Edit Program”. • Press ENTER to confirm. • Select “Select Programs”. • Press ENTER to confirm. • Select “Auto Pro Part 1”, “Auto Pro Part 2” or “Auto Pro Part 3”, and select which Slave program is to be sent.
Page 18
EDIT PROGRAM – Record Controller – Working With Built-In Program [continued] Example: Program 2 includes scenes: 10, 11, 12, & 13 Program 4 includes scenes: 8, 9, & 10 Program 6 includes scenes: 12, 13, 14, & 15 Auto Pro Part 1 is Program 2 Auto Pro Part 2 is Program 3 Auto Pro Part 3 is Program 6 The 3 Slave groups run the Auto Program in certain time segments.
D M X C H A N N E L F U N C T I O N S A N D V A L U E S ELATION WW PROFILE HP DMX Channel Values / Functions (4 DMX Channels) Specifications are subject to change without any prior written notice.
S P E C I F I C A T I O N S SOURCE High Power 130W Warm White LED 50,000 Hour Average LED Life* *May vary depending on several factors including but not limited to: Environmental Conditions, Power/Voltage, Usage Patterns (On-Off Cycling), Control, and Dimming. EFFECTS Electronic Strobe and 16bit Dimming Selectable Dimming Curve Modes...
Page 21
FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 22
DIMENSIONAL DRAWINGS Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
O P T I O N A L A C C E S S O R I E S ORDER CODE ITEM QUICK RIG CLAMP Low Profile Quick Release Clamp PHD019 Profile High Definition Lens 19° PHD126 Profile High Definition Lens 26° PHD236 Profile High Definition Lens 36°...