Measurements And A D Ju S Tm E N; Adjustment Procedure - Panasonic TH-103PF12E Service Manual

Gpf12d chassis
Hide thumbs Also See for TH-103PF12E:
Table of Contents

Advertisement

TH-103PF12E
10 Measurements and Adjustments

10.1. Adjustment Procedure

10.1.1.
Driver Set-up
10.1.1.1. Item / Preparation
1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
A spect: Full
Caution
1. First perform Vsus adjustment.
2. Confirmation of Vscn voltage should be performed after
confirmation of Vad adjustment.
When Vad=-135V, Voltage of Vscn is +10V ±4V.
10.1.1.2. Adjustments
Adjust driver section voltages. (Refer to the panel data on the
Panel Label).
Check or adjust the following voltages with the multimeter.
Name
Test Point
Vsus
TP V S U S
V sus ± 2V
(SC side)
(SC)
Vsus
TPVSUS
V sus ± 2V
(SS side)
(SS)
Ve**
TPVE (SS)
Ve ± 1V
Vda
TP9
70 V +1V, -2V
(P_M ain_1)
TP9
70 V +1V, -2V
(P_M ain_2)
Vad
TPVAD (SC)
-135V ± 1V
Vscn
TPVSCN
Vad_base:
(SC)
+ 145V ±4V
G ND_base:
+10V±6V
*See the Panel Label.
**See chap. 10.1.6.
50
Voltage
Volume
R em arks
*
VR251
(P_M ain_1)
*
VR251
(P_M ain_2)
*
VR16001
(SS)
Fixed
Fixed
V R 16600
(SC)
Fixed