Pal Phase; Pal R-Y Level; Pal Chroma; Secam Adjustment - Sony TRINITRON PVM-14M2U Service Manual

Color video monito
Hide thumbs Also See for TRINITRON PVM-14M2U:
Table of Contents

Advertisement

10-13. PAL PHASE (ACC OFF)
Note : 10-13. is not applicable to the group of models 3.
1) Conduct ACC OFF via MENU.
2) Adjust
IPHASBPALACCOPFI
in the same way as 10-12-4).
10-14. PALB-YPHASE
Note : Be sure to set ACC in the ON position before this adjust-
ment.
1) Input a PAL SP color bar.
2) Connect the probe of an oscilloscope to TP305.
3) Set the unit in the service mode.
4) Adjust
IB-YPHASBPAL!
so that the waveform of the R-Y anti-
PAL signal will be "O." (Fig.5-26)
Anti-PAL signal
8-Y (90. /90. )
-0-
*The signal waveform differs slightly every hour.
Adjust it to "0."
Fig. 5-26 B-Y OUT
10-15. PAL CHROMA (NORMAL)
l) Input
a
PAL color bar.
2) Connect the probe of an oscilloscope to IC404
®
PIN or TP402.
3) Set the unit in the service mode.
4) AdjustlCHROMA
PAL NORI
so that the peaks of waveforms will he
flush with each other. (Fig.5-27)
10-16. PAL CHROMA (ACC OFF)
Note : 10-16. is not applicable to the group of model 3.
l) Conduct ACC OFF via MENU.
2) Adjust
I
CHROMA PAL ACC OPFI
in the same way
as
10-15-4 ).(Fig.5-
27)
Make
Band D flush with each other.
A
__ D __ -----------·
B
C
t
40mVmax.
Fig. 5-27
10-17. PAL R-Y LEVEL
Note : Be sure to set ACC in the ON position before this adjust-
ment.
l) Input a PAL color bar.
2) Connect the probe of an oscilloscope to IC404
®
PIN or TP40l.
3) Set the unit in the service mode.
4) Adjust
IR-YLEVBLPAL!
so
that the peaks of waveforms will be
flush with each other as shown on the right. (Fig.5-28)
Make adjustment so that B=D.
IC404@PIN
60mV max.
A
+
B
D
20mVmax.
Fig. 5-28
11. SECAM adjustment
Note : Make adjustment after deflection adjustment.
Note : Subject to H-FREQ, H-BLK, VIDEO-PHASE, ANGLE,
BOW, H-DELAY, etc.
Note: 11. SECAM adjustment is not applicable to the group of
models 3.
11-1. HP WIDTH (NORMAL) adjustment
1) Input a SECAM color bar.
Note : The board is roughly adjusted in 11-1., and IC317
®
PIN
pulse width may be used for control.
2) Set the unit in the UNDER SCAN mode.
3) Set the unit in the service mode.
4) Adjust
IHP WIDTH NORI
so that the color section at the left edge of
the upper portion of the screen is about to disappear. (Fig.5-29)
BEZEL
Make adjustment so that colors are
about to disappear.
Fig. 5-29
-36-