Sensing Plate

1.
Open the flowmeter housing access door.
2.
Remove the sensing head cover and insert the sensing plate shaft fully into the
sensing head shaft socket*.
3.
Tighten the set screw/hex screw to secure the sensing plate.
Note:
*
Ensure the slot in the end of the shaft mates with the roll pin in the back of the
socket.

Viscous Damper

1.
Remove the two damper cover shipping screws. The damper cover will be held up
by a spring.
2.
If necessary, top up the damper to near overflowing with the damping fluid supplied.
3.
Store the damper cover shipping screws, remaining damper fluid, and filler bottle for
future use.
Note:
The damper must be full and free of air bubbles, with the damper cover in the
UP position, during flowmeter operation.