Download Print this page

General Safety - PRITY PLW 20 Technical Description And Operating Instructions

With water heat exchanger

Advertisement

For each room that is to be heated, preliminary calcu
and on the basis of its dimension, the thermal output of the
The fuel is wood pellets
Despite the presence of a c
ash, forming slag (cinder) in the ash, low
not be allowed.
Pellets are loaded in the hopper and via auger dosing device are fed into the specially constructed steel
repot (brazier) for burning, in accordance with the se ng selected at the controller.
A er start-up, the pellets in
electri
ng cartridge - igniter, which
Required amount of combu on air is fed through the repot (brazier) grate in a controlled manner.
It is supplied over a Ø50 mm PVC pipe.
The quan ty of the incoming air is measured and controlled by the electronic ow/ ow rate meter
for air.
The active fuel-air system compares the measured amount of incoming air with the necessary
amount of air to provide quality combus on process in the respec ve mode and brings it in conformity by
controlling the speed of the smoke fan.
This ensures quality combu on process completely independent on the parameters of the
chimney – length, height, resistance, pass-through capacity, d
providing the necessary air. In extreme situa ons – inadmissible or complete clogging, the stove will be
emergency shut down and A12 alarm will be triggered.
The ash remaining from the fuel combus on is collected in an ash box.
Flue gases are forcedly discharged into the chimney by means of an integrated smoke fan,
controlled in accordance with the se ngs and mode of opera on selected.
All processes are controlled in an intelligent manner by the integrated electronic unit – a dedicated
controller. It has the necessary opera on control sets - factory and user se ngs, programmed in it.
Aiming at preserva on of health, life and property of the user, there are safety fun ons provided,
which will stop the stove op
Cau on:
Usage and handling this appliance require certain minimum of knowledge and skills acquired.
All instruc ons provided by the manufacturer must cons tute an important and essen al part of
these knowledge and skills, be always available to the user and abided by in order to minimise or
completely exclude all possible risks and dangerous consequences.
This appliance may not be used by children less than 12 years old and individuals with reduced
physical, sensory or mental cap
instructed concerning the safe use of the appliance by the person in charge for their safety and are fully
aware of the hazards.
Children must not be allowed to play with the appliance.
No cleaning and servicing of the appliance may be done by children without supervision.
Always make sure that the stove is in a safe status, whether in opera on or during its down me.
Do not allow opening of the rebox door during opera on and in presence of re for more than 10
seconds.
During opera on, some surfaces are heated to high temperatures, which if touched accidentally or
erroneously, severe heat-related injuries can occur.
Modi ca ons of the appliance shall not be allowed.
When some part needs replacement, only original parts must be used.
Ø6
mm/30mm class 1. Quality of pellets is of par cular importance.
te, some pellets show various defects upon combu on: releasing more
lly loaded in the repot (brazier) are automa
erwards is switched o
on in cases of incorrect and foreseeably hazardous modes of opera on.

GENERAL SAFETY

s, or with insu
During opera on, the rebox door must always be closed.
STANDARDS AND LEGISLATION
ons of the heat losses will be performed
g body is to be selected.
ncy and calori c capacity. Use of other fuels and waste shall
or on the parameters of the pipework,
ient experience and knowledge, unless supervised or
14
ly ignited by the
the program.