Presence of any temporary, backup, permanent or other types of openings shall not be allowed,
apart from the ght and securely closed cleaning opening, situated at a su cient distance below the
connec on of the appliance's ue pipe and it must be suitable for cleaning purposes.
The stove must be equipped with means for supply of air, which is necessary to ensure the normal
combu on process and clean surrounding atmosphere. If the room is ght, an external air supply must be
provided in the area behind the appliance.
If the room is not ght and if it is permanently connected to other rooms, special measures to
provide external air supply may not be required.
Presence of any system that sucks out air (exhaust fan, range v
room where the appliance is installed.
Observa on of these instruc ons is obligatory in order to guarantee your own safety.
The pump is
built in,
The pump inlet must be
the radiators should go into the
The WHS constructed must provide an op on for emptying of the heat transfer agent (water) from
the system, at its lowest point.
WHS may be open or closed type, with membrane expansion vessel.
In
on of a safety valve is obligatory, which should not allow increasing the pressure in the
system (and the appliance) to more than 2 bar (0,2 MPa).
In
on of shut-o valve between the appliance outlet and the hot water inlet of the WHS shall
not be permi ed.
The connec on between the appliance and the expansion vessel must be direct, with no stop
valves, whatsoever. Autom
of its installa on.
Complete shut-down of all hea ng bodies for any reason is not designed and shall never be allowed
during opera on of the system.
Recircula on pump GRUNDFOS UPM3. el. 52W. Head: 4, 5, 6 and 7 m.
The pump is state-of-the-art and high-
the most suitable mode of opera on, mee ng the EUP 2015, Energy
selec on and the mode of opera on are in conformity with the output capacity of the stove. It has been
factory set up to the most suitable opera on mode and its modi ca on is not recommended, unless there
are good reasons for it.
Mount the control panel – display, as shown in the right-hand
picture and connect it to the motherboard using the enclosed
cable and cable jacks.
A er the nal comple on of all installa on works, make sure you
have read and understand all instruc ons.
The appliance must be connected to the electrical mains 230V
50Hz by means of a plug, wall-socket type Schuco and three-core
electrical cable with grounding / neutral conductor. The protec ve
connec on to neutral must be established and veri ed.
The room temperature sensor (next to the supply cable) must be installed outside the body of the stove in
order to provide correct measurement.

EXTERNAL AIR INTAKE

INFORMATION AND GUIDELINES
electrically wired and it is controlled by the controller.
ed with a lter and two ball valves. The returning, cooled water from
.
bleeding (self-bleeding) of the WHS system must be provided at the stage
ncy one, with electronic control and op on for selec on of
PREPARATION FOR INITIAL IGNITION
a on hood) is not allowed in the
16
iency Direc ve . The pump