Control And Data Connections - Crs-300 To Modem; Control Cabling Requirement (Regardless Of Driving Traffic Data Type); Table 4-1. Cdm-625/A Cable Usage (Rmi/Tmi) - Comtech EF Data CRS-300 Installation And Operation Manual

1:10 redundancy switch
Hide thumbs Also See for CRS-300:
Table of Contents

Advertisement

CRS-300 1:10 Redundancy Switch
Cables and Connections
4.4.3
Control and Data Connections – CRS-300 to Modem
Table 4-1 shows the TMI and applicable data and control cables that you will need for each of
the various data types.
Driving Traffic Data Type
Bal/Unbal
G.703
Balanced
(Sect. 4.4.3.2)
Unbalanced
G.703 – Quad E1
(Sect. 4.4.3.3)
ASI (Sect. 4.4.3.4)
EIA-422 (Sect. 4.4.3.5)
HSSI (Sect. 4.4.3.6)
LVDS (Sect. 4.4.3.7)
Wired-thru
(No Sub-Mux)
(Sect. 4.4.3.8.1)
Ethernet
(Sect. 4.4.3.8)
Wired-around
(Sub-Mux)
(Sect. 4.4.3.8.2)
4.4.3.1 Control Cabling Requirement (Regardless of Driving Traffic Data
Type)
For RMI connections: The Control/Data Cable CA/WR0066 (DB-25F to DB-25M, 6') provides the
serial communication path between the Redundant CDM-625/A and the Switch (via the CRS-310
RMI) for all driving traffic data types. You must always use this cable.
For all driving traffic data types, see Figure 4-9 through Figure 4-11 and do these steps to
connect and secure the CA/WR0066 cable between the Redundant CDM-625/A and the Switch
CRS-310 RMI:
DB-25F connector labeled "Data Interface" on Redundant CDM-625/A, to
DB-25M connector labeled "P1" on the Switch CRS-310 RMI.
For TMI connections: Depending on the driving data traffic type, in addition to its use as a
control cable between the Redundant CDM-625/A and the CRS-310 RMI, you may use the

Table 4-1. CDM-625/A Cable Usage (RMI/TMI)

CDM-625/A Cable Usage
(see Appendix B. CABLE DRAWINGS for cable details)
CRS-310 RMI / Cable(s)
Control: CA/WR0066
Data: CA-0000072
Control: CA/WR0066
Data: CA-0000072
Control: CA/WR0066
Data: PL/0813-8 (2X)
Control: CA/WR0066
Data: CA-0000073
Control: CA/WR0066
Data: PL/0813-8 (2X)
Control/Data: CA/WR0066
Control/Data: CA/WR0066
Control/Data: CA/WR0066
Control: CA/WR0066
Data: CA-0000121
Control: CA/WR0066
Data (by User): CAT5 to
10/100/1000 Switch
TMI / Cable(s)
CRS-330/340
CRS-325
CRS-365D
CRS-325
CRS-316
CRS-340
CRS-336
CRS-340
CRS-316 or
CRS-336
N/A
4–21
MN/CRS300.IOM
Revision 19
Control: CA/WR0066
Data: CA-0000072
Control: CA/WR0066
Data: CA-0000072
Control: CA-0000069
Data: PL/0813-8 (2X)
Control: CA-0000069
Data: CA-0000136 (2X)
Control: CA-0000069
Data: PL/0813-8 (2X)
Control: CA-0000069
Data: CA/WR0066
Control: CA/WR0066
Data:
Control: CA-0000069
Data: CA/WR9189-6 with CIC-60
Adapter Module
Control/Data: CA/WR0066
Control: CA-0000069
Data: PP/CAT5FF7FTGY
N/A

Advertisement

Table of Contents
loading

Table of Contents