SPECIAL FEATURES :
VFD V & Hz readings.
Paper-White
Backlight LCD Display
Record MAX / MIN readings.
Display Hold Function.
Dual Digital
Display.
GENERAL SPECIFICATIONS :
Sensing : AC, True RMS
Display : 3-5/6 digits 6000 Counts Backlight LCD Display.
Polarity : Automatic
Update Rate : 5 per second nominal
61 Segments Analog Bar Graph : 60 per second max.
Power Supply: Four Alkaline AA batteries
Power Consumption: 4.5mA typical except : ACV
Earth Continuity Test : 110mA @20
Tester can perform at least 3000 Earth Continuity Test measurements with new alkaline batteries at
room temperature. These are standard test of 1
Insulation Resistance @ 1mA Test Current :
50V output Voltage : 25mA, 100V output Voltage : 45mA
250V output Voltage : 85mA, 500V output Voltage : 170mA
1000V output Voltage : 440mA
Tester can perform at least 950 Insulation Tests with new alkaline batteries at room temperature.
These are standard tests of 1000V into 1M
Operating Temperature : -10ºC ~ 40ºC
Relative Humidity : Maximum relative humidity 90% for temperature
up to 28ºC decreasing linearly to 50% relative humidity at 40ºC.
Pollution degree : 2
I
P Rating : IP40
Storage Temperature : -20ºC ~ 60ºC, < 80% R.H. (with battery removed)
Altitude : Operating below 2000m
Temperature Coefficient : Nominal 0.15 x (specified accuracy)/ °C @(-10ºC~18ºC or 28ºC~40ºC),
or otherwise specified.
Low Battery: approx. 4.6V
APO Timing: Idle for 20 minutes
APO Consumption: 50 A typical
Auto or Manual-ranging mode.
Auto Power Off.
Dimension: 208(L) X 103(W) X 64.5(H) mm with holster
Weight: 635 gm with holster.
SAFETY :
Safety : Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0,
IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2
No. 61010-1-12 Ed. 3.0 to CAT III 1000 V AC & DC and CAT IV 600V AC & DC.
Compliance to IEC/EN61557; 2007 (per CE requirements, not certified by UL or ETL) : IEC/EN61557-1, IEC/EN61557-2 & IEC/EN61557-4 where applicable.
E.M.C. : Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
In an RF field of 3V/m:
Total Accuracy = Specified Accuracy + 25 digits.
Performance above 3V/m is not specified.
Transient Protection : 8KV(1.2/50 S Surge)
Overload Protections :
Insulation Resistance & mA : 0.4A/1KV, IR 30kA or better
Earth Continuity Test
V
mV,
& Others : 1000 Vrms
ACCESSORIES :
Test probe pair, BRP21S2-C Remote probe, Alligator clip pair, Holster, User manual & Carrying Case.
OPTIONAL
ACCESSORIES :
D:/Chhaya/My Documents/Chhaya/backup/catlogs/NEW CAT/2013-2014/KM 878.cdr
® ®
TRUE RMS DIGITAL INSULATION MULTIMETER
Autoranging.
LOCK-Test mode for Insulation Resistance &
Earth Continuity Test.
TM
BeepJack audible & visible input warning.
Remote Probe for insulation Resistance &
Earth Continuity Test.
+Hz
& VFD ACV : 7.0mA
with a duty cycle of 5 seconds on & 25 seconds off.
with a duty cycle of 5 seconds on and 25 seconds off.
: 0.25A/1KV, IR 30kA or better
: 1100Vrms
BKB32 banana plug to type-K socket plug adaptor & Magnetic hanger.
+Hz
range, 220mA @2.0
range.
All Specifications are subject to change without prior notice
MODEL KM 878
24 Functions 79 Ranges
Preliminary Data

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KM 878 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kusam-meco KM 878

  • Page 1 Test probe pair, BRP21S2-C Remote probe, Alligator clip pair, Holster, User manual & Carrying Case. OPTIONAL ACCESSORIES : BKB32 banana plug to type-K socket plug adaptor & Magnetic hanger. All Specifications are subject to change without prior notice D:/Chhaya/My Documents/Chhaya/backup/catlogs/NEW CAT/2013-2014/KM 878.cdr...
  • Page 2 ELECTRICAL SPECIFICATIONS : KM 878 Accuracy is ± (% of reading digits + number of digits) or otherwise specified, at 23 C ± 5 C & less than 80%relative humidity. True RMS voltage & current accuracies are specified from 1 % to 100 % of range or otherwise specified.
  • Page 3 ® ® G-17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015. INDIA. Sales Direct.: 022-24156638, Tel. : 022-24124540, 24181649, Fax : 022-24149659 Email : kusam_meco@vsnl.net, Website : www.kusamelectrical.com An ISO 9001:2008 Company D:/Chhaya/My Documents/Chhaya/backup/catlogs/NEW CAT/2013-2014/KM 878.cdr...
  • Page 4 ® USE TRUE RMS WHEN MEASURING AC WAVEFORMS The waveforms on today’s AC power lines are anything but clean. Electronic equipment such as office computers, with their switching power supplies, produce harmonics that distort power-line waveforms. These distortions make measuring AC voltage inaccurate when you use an averaging DMM.
  • Page 5: Trms Digital

    ¬ Digital Sound Level Meter & Sound Level Calibrator ¬ Digital contact & Non-contact Type Tachometer ¬ Digital Non-contact (infrared) Thermometer ¬ Maximum Demand Controller/Digital Power Meter MODEL - KM 878 ¬ Digital Hand Held Temperature Indicators ® G 17, Bharat Industrial Estate, T. J. Road, Sewree (W), Mumbai - 400 015.
  • Page 6: Table Of Contents

    ® ® TRMS DIGITAL TABLE OF CONTENTS INSULATION MULTIMETER TITLE PAGE NO. MODEL - KM 878 Safety............Cenelec Directives........III. Special Features......... IV. General Specifications....... Product Description ........VI. Operation............ VII. Maintenance..........VIII . Test Certificate........... IX. Warranty............
  • Page 7: Safety

    ® ® I. SAFETY : The meter protection rating, against the users, is double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, IEC/ This manual contains information and warnings that must be EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/ followed for operating the instrument safely and maintaining the CSA-C22.2 No.
  • Page 8: Cenelec Directives

    ® ® CAUTION : IV. GENERAL SPECIFICATIONS : Disconnect the test leads from the test points before changing Display : 3-5/6 digits 6,000 counts functions. Always set the instrument to the highest range and work Polarity : Automatic downward for an unknown value when using manual ranging mode. Update Rate : 5 per second nominal 61 Segments Bar graph : 40 per second max...
  • Page 9 ® ® SAFETY : Insulation Resistance @1mA test current : 50V output voltage : 25mA Safety : Double insulation per IEC/UL/EN61010-1 100V output voltage : 45mA Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0, 250V output voltage : 85mA IEC/EN61010-2-033 Ed. 1.0, IEC/UL/ 500V output voltage : 170mA EN61010-031 Ed.
  • Page 10 ® ® 1kHz ~ 3kHz DCmV : 6.000 V Range Accuracy ±(2%rdg + 3dgts) Resolution 60.00 V ±(0.5%rdg + 3dgts) 60.00 mV 600.0 V 100 mV ±(0.1%rdg + 3dgts) Unspecified 600.0 mV 100 mV 1000 V Input Impedance : 10MW, 140pF nominal 3kHz ~ 5kHz 6.000 V ±(4%rdg + 5dgts)
  • Page 11 ® ® DCmA : Resistance : Range Accuracy Resolution Range Accuracy Resolution 60.00 mV ±(0.9%rdg + 5dgts) 600.0 100 m ±(0.5%rdg + 3dgts) 600.0 mV 100 mV 6.000 K Burden Voltage : 3.0 mV/mA ±(0.9%rdg + 2dgts) 60.00 K 600.0 K Insulation Resistance : ±(1.2%rdg + 3dgts) 6.000 M...
  • Page 12: Product Description

    ® ® V. PRODUCT DESCRIPTION : Hz Line Level Frequency : Note : Top of the line model is used as representative for illustration Sensitivity Function Range Range purposes. Please refer to your particular model for function (Sine RMS) availability. 10Hz ~ 50kHz 10Hz ~ 100kHz 1.
  • Page 13: Operation

    ® ® VI. OPERATION : W Resistance, Continuity CAUTION : Press the SELECT button momentarily to toggle the functions. Last Before and after hazardous voltage measurements, test the voltage selection will be saved as power up default for repeat measurement function on a known source such as line voltage to determine convenience.
  • Page 14 ® ® Diode Test, Capacitance Function DCmV, ACmV functions Press the SELECT button momentarily to toggle the subject Press the SELECT button momentarily to toggle the functions. Last functions. Last selection will be saved as power up default for selection will be saved as power up default for repeat measurement repeat measurement convenience.
  • Page 15 ® ® Temperature functions Earth Continuity Test Function AUTO AUTO Press SELECT button momentarily to toggle ºC and ºF readings. This function measures the Last selection will be saved as power up default for repeat Resistance values of earth measurement convenience. connection &...
  • Page 16 ® ® The results of measurements can be adversely affected by Lock-Test mode is recommended for continuous measurement. To impedances of additional operating circuits connected in parallel or apply, press the LOCK button momentarily to display the by transient currents. annunciator LOCK before pressing the TEST button momentarily.
  • Page 17 ® ® Setup as illustrated below. TEST TEST AUTO AUTO AUTO TEST TEST LOCK LOCK Select an intended test voltage of 50V, 100V. 250V. 500V or 1000V. LOCK LOCK press the RANGE (Test Voltage) button momentarily Test Voltage Test Voltage Test Voltage LOCK LOCK...
  • Page 18 ® ® Lock-Test mode is recommended for continuous measurements. Smooth mode (Insulation function only) : To apply, press the LOCK button momentarily to display the Smooth mode displays the running average of the last eight annunciator LOCK before pressing TEST button measured readings having changes within 300 counts in sequence.
  • Page 19: Maintenance

    ® ® Set Beeper Off : Press the RANGE button while turning the If the instrument voltage-resistance input terminal has subjected to high voltage transient (caused by lightning or switching surge to the meter on to temporarily disable the Beeper feature. Turn the rotary system) by accident or abnormal conditions of operation, the series switch OFF and then back on to resume.
  • Page 20: Test Certificate

    ® MUMBAI WARRANTY Each “KUSAM-MECO” product is warranted to be free from defects in TEST CERTIFICATE material and workmanship under normal use & service. The warranty period is one year (12 months) and begins from the date of despatch of TRMS DIGITAL INSULATION MULTIMETER goods.

Table of Contents