13. COIN SELECTOR

HANDLING THE COIN JAM
If the coin is not rejected when the REJECT button is pressed, open the coin chute door and
open the selector gate. After removing the jammed coin, put a normal coin in and check to see
that the selector correctly functions.
CLEANING THE COIN SELECTOR
Remove and clean smears by using a soft
cloth dipped in water or diluted chemical
detergent and then squeezed dry.
Never apply machine oil, etc. to the Coin
Selector.
After cleaning the Coin Selector, insert a
regular coin in the normal working status
and ensure that the Selector correctly
functions.
The coin selector should be cleaned once every 3 months.
When cleaning, follow the procedure below:
1
Turn the power for the machine OFF. Open the
coin chute door.
2
Remove the coin selector from the coin chute door.
Open the gate and dust off by using a soft brush
3
(made of wool, etc.).
4
Remove and clean smears by using a soft cloth
dipped in water or diluted chemical detergent and
then squeezed dry.
5
Remove the CRADLE.
When removing the retaining ring (E ring), be very
careful so as not to bend the rotary shaft.
6
Remove stain from the rotary shaft and shaft
receiving portions by wiping off with a soft cloth,
etc.
7
After wiping off as per above, further apply a dry
cloth, etc. to cause the coin selector to dry
completely.
COIN INSERTION TEST
Once every month, when performing the
Coin SW Test, simultaneously check the
following:
Does the Coin Meter count satisfactorily?
Does the coin drop into the Cashbox correctly?
Is the coin rejected when inserted while keeping the
Reject Button pressed down?
www.seuservice.com
Insert a coin
while keeping
the Reject But-
ton
pressed
down and check
if it is rejected.
COIN METER
80
GATE
FIG. 13 a
CRADLE