System Setup

5.1

Power-up Sequence

When the 1050 Control is connected to the Sub-base,
the 1050 Control initiates a 90-120 second power-up
sequence. During the power-up sequence, the Screen
Calibration option is available for five seconds (Screen
Calibration is available for five minutes if the screen has
never been calibrated and following a Restore Factory
Defaults command).
If the screen is not pressed within five minutes, the 1050
Control will default to previously stored Screen Calibration
settings. The 1050 Control is factory calibrated and can be
recalibrated at any time by rebooting the 1050 Control.
5.2

Guided Setup Wizards

The 1050 Control features two Setup Wizards, the
Installation Wizard and the User Setup Wizard. The
Installation Wizard guides installers through the installation
and configuration process, and the User Step Wizard
guides Homeowners through user-configurable settings.
INSTALLATION WIZARD
MENU ITEMS
Date and Time
Installer Setup
Service Reminders
Dealer Identification Code
5.3

Installer Setup Screens

From the Installer Setup screens, individual parameters are configured and modified. Use the up and down arrows to scroll
through the groups of settings. To change a setting contained in a particular group, press Edit and press Next to navigate to
the desired setting. Press Save to save changes or Exit to discard changes.

5.3.1 Group 1 - Standard Settings*

MENU ITEM
Outdoor Unit Type
Outdoor Unit Stages
Compressor Type
Indoor Unit Type
Indoor Heat Stages
Indoor Blower Type
* All Group 1 settings will be auto-configured for fully communicating systems.
8
DESCRIPTION
Set the current date, time and select whether Daylight Saving Time is on or off.
Configure the basic equipment components installed and customize how the 1050 Control operates. See Installer
Setup Screens for detailed information on installer setup options.
Various service reminders can be enabled on the 1050 Control based on the system configured. Reminder options
are System, Filter, Ventilation, UV Light and Humidifier. The frequency of each reminder can be selected based on
calendar or run time days.
The dealer identification code is used to populate the Dealer Contact Information and associate this device with
a Nexia Dealer Portal account. Enter the primary phone number of the dealership to activate this feature. Only
controls connected to the Internet will auto-populate the dealer information. See Section 5.6 for more informatioin
OPTIONS [DEFAULT]
None, Cooling Only, Heat Pump
Single Stage, Two Stage, Variable
Single Compressor Two Stage, Two Compressor
Two Stage
Gas/Oil, Electric, Hydronic
1, 2, 3, Modulating
Non-Variable, Variable
user Setup Wizard
The User Setup Wizard is accessed navigating to
Home>Menu>Settings>User Setup Wizard. By following the
navigational steps and screen prompts, homeowners are
guided through the Display, Schedules, Guided Schedule,
Network, Nexia and Weather configuration screens. Each
of these menus may also be accessed individually. Refer
to the User Guide for detailed information on user settings.
Installation Wizard
The
Installation
Wizard
Control is powered on for the first time, or when the
Restore Factory Defaults function is invoked.
Installation Wizard can also be invoked directly in the
Service
Menu
at
(Home>Menu>Service>Technician
Access>Proceed>Installation Wizard).
By following the navigational steps and screen prompts,
installer's are guided through setting the date and time,
completing the installer settings, setting various reminders,
and assigning a Dealer Code. Each of these menus can
be individually accessed after completing the Installation
Wizard.
DESCRIPTION
Select the type of outdoor unit installed
Select the number of outdoor unit stages
Select the compressor type for multi-stage outdoor units
Select the type of indoor unit installed
Select the number of indoor heat stages
Select the indoor blower type (Constant Torque motors are
considered non-variable speed)
appears
when
the
1050