Group 4* - Accessories Settings - American Standard AccuLink Platinum 1050 Installation Manual

Communicating connected control
Hide thumbs Also See for AccuLink Platinum 1050:
Table of Contents

Advertisement

Installation Guide

5.3.5 Group 4* - Accessories Settings

* If Zoning is enabled, this group will be called Group 5.
MENU ITEM
Filtration Type Installed
Number Of Air Cleaners installed
Humidifier Installed 1
Humidifier Type
Humidifier Control
Humidifier Fan Action
Airflow During Humidifier Only Mode
UV Light Installed 1
Ventilation Installed 1
Ventilation - Select Aux Contact
Outdoor Temperature Ventilation Override
Ventilator Fan Action
Ventilation - Minimum Outdoor Temperature
Ventilation - Maximum Outdoor Temperature
Minimum Ventilation Runtime
Accumulate Overridden Runtime
Accumulate Period
Dehumidifier Installed
Dehumidifier - Select AUX Contact
Dehumidifier Control Options
Run System Fan With Dehumidifier Request
1 Requires Relay Panel
2 Only one method of recovery can be enabled.
12
OPTIONS [DEFAULT] DESCRIPTION
[No Comm Air Cleaner
Discovered], Comm Air
Select the filter type installed
Cleaner Discovered Air
Cleaner, [Media Filter]
[1], 2
Select the number of Comm Air Cleaners installed
[No], Yes
Select whether a humidifier is installed
[Powered/Bypass], Steam
Select what type of humidifier is installed
Select how the humidifier will be controlled (Outdoor temperature
[RH Control], Frost Control
sensor must be connected and enabled to allow this setting to be
selected)
[Humidify with Active Heat
Select when the humidifier is allowed to operate (Humidification is
Call], Humidify without
disallowed during cooling mode or when the System Mode is Auto but
Active Heat Call
the last call was cooling)
Select the desired airflow when the humidifier is operating without an
35% - 100% [50]
active call for heat
[No], Yes
Select whether a UV Light is installed
[No], Yes
Select whether a ventilation system is installed
Aux 1, Aux 2
Select which set of aux contacts is controlling the ventilation system
Select whether an outdoor temperature override is allowed (Outdoor
[Disable], Enable
temperature sensor must be connected and enabled to allow this
setting to be selected)
[Ventilate with Blower],
Select whether the indoor blower operates on a call for ventilation
Ventilate without Blower
-10°F - 50°F [0°]
Select the minimum outdoor temperature that ventilation is allowed
80°F - 110°F [100°F]
Select the maximum outdoor temperature that ventilation is allowed
0 - 60 Minutes [5 Minutes]
Select the minimum runtime per hour for ventilation system
[No], Yes
Select whether the overridden ventilation runtime will be made up
[4 hrs -recover based on
OD conditions],
24 hrs - recover based on
Select when to recover missed ventilation runtime due to outdoor
OD conditions,
conditions exceeding the minimum/maximum outdoor temperate for
4 hrs - recover to maintain
ventilation (The first two options will not meet AHRAE 62.2 standard for
min ventilation,
minimum ventilation requirements)
24 hrs - recover to maintain
min ventilation
[None], Yes
Select whether a dehumidifier is installed
Aux 1, Aux 2
Select which set of aux contacts is controlling the dehumidifier
[Stand Alone Operation],
Select control of Dehumidifier
With Call for Clg Only
Select whether the indoor blower operates with a call for
[Yes], No
dehumidification
11-HD15D1-5-EN