NOTE: Always fill the cylinder as slowly as possible (do not exceed 300 PSI
/ 20.7 BAR per minute) by turning the handwheel of the supply valve slowly
to control the rate of fill. Rapid filling will generate heat and will result in an
incomplete fill after the cylinder cools. If the cylinder is warm to the touch
afterward, the fill rate was too rapid.
5. While supporting the cylinder with one hand, very slowly open the
compressor valve to begin filling (do not exceed a fill rate of 300 PSI /
20.7 BAR per minute). Make sure the dial or pin pressure gauge shows
that the cylinder is filling properly.
6. When air can no longer be heard flowing from the compressor fill hose into
the SEA, completely open the compressor valve. Verify the cylinder has been
filled to its maximum capacity as marked.
7. While holding the first stage and fill adapter secure, close the handwheel
on the compressor valve. Close the handwheel on the SEA and depressurize
the system.
8. Open the bleed valve screw on the fill adapter to relieve the line pressure.
9. While supporting the SEA cylinder with one hand, unscrew the adapter nut
and remove it from the fill port. Replace protector cap on the threaded male
fitting of the fill adapter.
10. Return the fill adapter to its storage location.
11. Check that the o-ring on the fill port cap is present, not damaged and seated
evenly at the base of the cap. Thread the fill port cap back into the fill port until
finger-tight.

Additional Filling Options

Several filling options for the SEA are available through Capewell / Aerial
Systems LLC. For additional information please contact:
Capewell / Aerial LLC
4298 JEB Stuart Highway
Meadow of Dan, Va 24120
Phone: 276-952-2006
Website: capewellaerialsystems.com
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sea lv2

Table of Contents