Prelude
INSTRUCTIONS FOR USE
...with people in mind
04.BB.01_6US.CA . June 2012

Advertisement

Table of Contents
loading

Summary of Contents for Arjohuntleigh Prelude

  • Page 1 Prelude INSTRUCTIONS FOR USE ...with people in mind 04.BB.01_6US.CA . June 2012...
  • Page 2 Design Policy and Copyright ® and ™ are trademarks belonging to the ArjoHuntleigh group of companies. © Arjo Hospital Equipment AB 2011. As our policy is one of continuous improvement, we reserve the right to modify designs without prior notice.The content of this publication may not be copied...
  • Page 3: Table Of Contents

    Transfer using an ArjoHuntleigh standing and raising aid..18 Disinfection Instructions ............20 Disinfecting the Prelude ............24 Disinfecting lift hygiene chair in the Prelude ......26 Care and Preventive Maintenance........... 28 Technical Specification ............32 Labels on the Prelude .............. 34 Parts and Accessories .............
  • Page 4: Foreword

    If you require further information, please con- tact ArjoHuntleigh for comprehensive support ArjoHuntleigh equipment. and service programs to maximize the long- Your Prelude is a part of a series of quality term safety, reliability and value of the prod- products designed especially for hospitals, uct.
  • Page 5: Intended Use

    The safe working load (SWL) should not exceed 125 kg (275 lbs). • Active and semi-active residents (i.e. able to sit upright self supported on the side of a bed or toilet) can use the Prelude. Correct transfer aid shall be used, if needed.
  • Page 6: Safety Instructions

    WARNING Make sure to refer to the compatible products IFU when using it together with the Prelude to avoid bodily injury. WARNING To prevent cross-contamination, always follow the disinfection instruc- tions in this Instructions for Use.
  • Page 7: Preparations

    2 If any part is missing or damaged - do NOT 2 The packaging should be recycled accord- use the product. ing to local regulations. WARNING 3 Install the Prelude by qualified personnel. To prevent cross-contamination, See separate Assembly and Installation always follow the disinfection Instructions.
  • Page 8: Parts Designation

    Parts Designation 1 Back rest 2 Safety belt 3 Lock (chair in inner position) 4 Lock (chair in outer position) 5 Grab bar 6 Chair 7 Chair rails 8 Drainage 9 Toilet function 10 Splash guard (2 types) 11 Hair wash basin (Accessory)
  • Page 9 Model without toilet function Model with toilet function...
  • Page 10: Product Description/Functions

    3 Make sure the safety belt is close to the res- The chair of the Prelude can slide back and idents body. forth and automatically locks to its outer and inner position.
  • Page 12: Assist Resident Into The Prelude

    Non-ambulatory residents are recommended to enter into the Prelude with the help of an Arjo- Huntleigh lift hygiene chair or a standing and To prevent scalding, always check raising aid.
  • Page 14: Transfer Directly From Wheelchair

    1 Remove the splash guard and slide the chair to its outer locked position. To prevent scalding, always check 2 Remove the seat in the Prelude with toilet the water temperature with your function if showering an incontinent resi- naked hand before directing the dent.
  • Page 16: Transfer Using An Arjohuntleigh Lift Hygiene Chair

    Raise the lift hygiene chair and push it care- (See Fig. 5) fully as far as possible into the Prelude. (See Fig. 2) 10 Place a towel around the residents shoul- ders after having washed and rinsed the 4 First, apply the castor brakes and lower the upper body.
  • Page 18: Transfer Using An Arjohuntleigh Standing And Raising Aid

    (See Fig. 1-2) Release the outer lock and carefully push the chair slightly inwards. Help the resident 2 Remove the seat in the Prelude with toilet to place their feet inside the Prelude before function if showering an incontinent resi- sliding the chair to its inner locked position.
  • Page 20: Disinfection Instructions

    Instructions for Use. If you have any questions regarding disinfect- ing the equipment or wish to order disinfecting fluid, please contact your ArjoHuntleigh Cus- WARNING tomer Service. Accessories for disinfecting the Prelude •...
  • Page 21 Make sure that the water circulates in the Shower & Disinfection panel on a daily basis even if the Shower & Disinfection panel and the Prelude are not used; and par- ticular to make sure to remove any water that may be left behind in the hose.
  • Page 22 6 Grab the disinfection spray handle. 7 Spray disinfection fluid in the Prelude while keeping an eye on the flow meter. 8 Check the mix ratio on the flow meter so that it is in accordance with the setting range stated in this IFU.
  • Page 23 Arjo Clean (50)
  • Page 24: Disinfecting The Prelude

    3 Remove all plastic parts from the chair and valve or a flush button. place them at the bottom of the Prelude: 18 Wipe the Prelude dry with a clean cloth or • Lift the seat insert straight upwards. towel to remove excess water.
  • Page 25 Arjo Clean (50)
  • Page 26: Disinfecting Lift Hygiene Chair In The Prelude

    Lift the seat insert straight upwards. valve or a flush button. (See Fig. 2) 19 Wipe the lift hygiene chair and the Prelude • Remove the seat halves by pressing from dry with a clean cloth or towel to remove the outside and lift on the inside.
  • Page 27 Arjo Clean (50)
  • Page 28: Care And Preventive Maintenance

    Care and Preventive Maintenance The Prelude is subject to wear and tear, and the following actions must be performed when specified to ensure that the product remains within its original manufacturing specification. WARNING To avoid malfunction resulting in injury, make sure to conduct regular inspections and follow the recommended maintenance schedule.
  • Page 29 Check mechanical attachments Check that the latest updates have been implemented NOTE All Caregiver Obligations are to be checked when performing the Qualified Personnel Service. NOTE If the product does not work as intended, immediately contact your local ArjoHuntleigh representive for support.
  • Page 30 - Make sure no cracks or sharp edges have developed that could cause the resident or caregiver injury or that has become unhygienic. - Clean the Prelude and its plastic parts. - Replace damaged parts. (Figure 2.) • Perform a functionality test Check the sliding function of the chair and test the fitting of the splash guard.
  • Page 31 Arjo Clean (50)
  • Page 32: Technical Specification

    950 mm (37 3/8”) Width 770 mm (30 1/4”) Depth 1130 mm (44 1/2”) Water supply requirements for Prelude with toilet function Cold water G3/4” male (customers connection) Warm water G3/4” male (customers connection) Connect with shut off valves, 3/4” connection Max.
  • Page 33 500 hPa to 1060 hPa Storage Recycling The device should be recycled according to national regulations. Package Wood and corrugated cardboard recyclable Prelude Metal and plastic parts shall be sepa- rated and recycled according to (WEEE) and according to markings on the unit.
  • Page 34: Labels On The Prelude

    Labels on the Prelude On the data and approval labels you will find the following information: Defines the maximum total Safe working load of resident, water or load any other load that may be handled by the Prelude. Read the IFU before use...
  • Page 35 XXXXXX= running numbers 1103 = year and month Product no BBA1250-04 Serial no 1103XXXXXX Made by Arjo in Eslov, Sweden 010115 Identification Label MODEL: BBA 12XX-04 SWL Safe Working Load 125 kg / 275 lb Patents protection of design L 25532 CSA B45.0-99 GRANTED AND/OR APPLIED CSA B125-98...
  • Page 36: Parts And Accessories

    Parts and Accessories ArjoHuntleigh Arjo Clean Arjo Clean Disinfectant Hair Wash Basin Safety Belt 12 X 1 Litre Bottles BBA0001-90 8662039-03 PRB2500...
  • Page 37 Intentionally left blank...
  • Page 38 Intentionally left blank...
  • Page 39 AUSTRALIA FAR EAST POLSKA ArjoHuntleigh Pty Ltd ARJO Far East Limited ArjoHuntleigh Polska Sp. z o.o. 78, Forsyth street Unit 3A, 4/F., block B Hoi Luen ul. Ks Piotra Wawrzyniaka 2 O’Connor Industrial Centre PL 62-052 KOMORNIKI (Poznan) AU-6163 Western Australia...
  • Page 40 GETINGE GROUP is a leading global provider of products and systems that contribute to quality enhancement and cost efficiency within healthcare and life sciences. We operate under the three brands of ArjoHuntleigh, GETINGE and MAQUET. ArjoHuntleigh focuses on patient mobility and wound management solutions.