Hussmann RDI-27 Installation & Operation Manual page 51

Refrigerated drop in display
Table of Contents

Advertisement

Auxiliary table for settings
(quick-setup)
Preset settings (o62)
Temperature (SP)
Max. temp. setting (r02)
Min. temp. setting (r03)
Sensor signal for thermostat. S4% (r15)
Alarm limit high (A13)
Alarm limit low (A14)
Sensor signal for alarm funct.S4% (A36)
Interval between defrost (d03)
Defrost sensor: 0=time, 1=S5, 2=S4 (d10)
DI1 con g. (o02)
Sensor signal for display view S4% (017)
Override
The controller contains a number of functions that can be used to-
gether with the override function in the master gateway / System
Manager.
Function via data communication
Start of defrosting
Coordinated defrost
Night setback
Light control
Ordering
Type
AK-CC 210
EKA 178A
EKA 179A
EKA 181C
EKA 182A
EKA 163A
22
Defrost stop on
time
1
4°C
6°C
2°C
10°C
-5°C
6 h
0
Case cleaning (=10)
Functions to be used in the gateway's
override function
Defrost control
Time schedule
Defrost control
Day/night control
Time schedule
Day/night control
Time schedule
Manual
RS8EP502
©
Danfoss
Case
Defrost stop
Defrost stop on
on S5
2
3
2°C
-24°C
4°C
-22°C
0°C
-26°C
100%
8°C
-15°C
-5°C
-30°C
100%
6h
12h
1
1
100%
Used parameter in AK-CC 210
- - - Def.start
- - - HoldAfterDef
u60 Def.relay
- - - Night setbck
o39 Light Remote
Function
Refrigeration controller without data communica-
tion but prepared for mounting of one module
Data communication module
MOD-BUS
Data communication module
LON RS 485
Battery module that will protect the clock in case
of lengthy power failure
Copy key EKC - EKC
External display for AK-CC 210
12-2015
51
Room
Defrost stop
time
on S5
4
5
6°C
3°C
8°C
5°C
4°C
1°C
0%
10°C
8°C
0°C
0°C
0%
8h
8h
0
1
Door function (=3)
0%
Code no.
230 V a.c
084B8520
115 V a.c.
084B8534
084B8564
084B8565
084B8577
084B8567
084B8562
6
-22°C
-20°C
-24°C
-15°C
-30°C
12h
1
AK-CC 210