8.c
Digital input alarm (selection "Digital input 1" or "Digital input 2")
Alarm related to digital input: the relay activates with digital input active.
8.d
Sensor failure alarm (selection"Sensor failure")
Sensor failure alarm: the relay activates in case of strain-gauge failure.
8.e
Remote control alarm (selection "Remote control")
The relay activates writing 1 on Modbus Word 1018 for alarm 1 and on Modbus
word 1019 for alarm 2. Writing 0 the relay deactivates.
8.f
Gross weight alarm (selection "Gross weight")
The relays are activated when gross weight is selected (TARE function enabled
by parameter 136).
8.g
Net weight alarm (selection "Net weight")
The relays are activated when net weight is selected (TARE function enabled by
parameter 136).
8.h
Stable weight alarm (selection "Stable weight")
The relays are activated when the process reading is stable (stability function
enabled by parameters 137 and 138).
8.i
Sum alarm (selection "Sum")
Absolute alarm managed on the sum value. For functioning details, refer to the
graphics of the process absolute alarm.
8.j
Alarm " calibration % control " (option "Calibration %")
This option is available only for Alarm 2. Relay activates when, during calibration
proceeding "Calibration on full-scale % value", the calibration of sensor upper
limit is activated by pressing the key. At the end of calibration, relay will
automatically deactivate.
User manual - DP400S -