Turning On The Fryer; Turning Off The Fryer - Vulcan-Hart GRM SERIES Installation And Operational Manual

Gas fryers
Hide thumbs Also See for GRM SERIES:
Table of Contents

Advertisement

Available languages

Available languages

GRM SERIES GAS FRYERS
1. Open the door.
2. Make sure that thermostat is set to OFF. The thermostat is located behind the door.
3. Push the gas control valve knob and turn to OFF (see figure below, view A). Wait 5
minutes for unburned gas to vent.
4. Push and turn gas control valve knob to the "L" in PILOT (see figure below, view B).
5. While still holding the knob in, light the pilot with a lit flame. Continue to depress the
knob until pilot remains lit when knob is released. If the pilot does not remain lit, repeat
step 3 through 5.
6. Depress and turn gas control knob to ON (See figure below, view C).
7. If gas supply is interrupted, repeat steps 2 through 6.
 Set the temperature knob to desired temperature.
 After the set temperature has been reached, the thermostat shuts off the gas flow
to burners.
 The pilot remains lit. The burners will cycle on and off, maintaining the set
temperature.
1. Turn the thermostat OFF.
2. To keep the pilot lit, turn the gas valve to "L" in Pilot.
3. To shut off all gas to the system, including the pilot, turn the gas valve knob to the
OFF position.
VULCAN-HART

TURNING ON THE FRYER

TURNING OFF THE FRYER

-11-