Controls; Integrated Control; Optional Main Controls - Venmar 41502 User Manual

Heat recovery ventilators and energy recovery ventilators
Hide thumbs Also See for 41502:
Table of Contents

Advertisement

2.0 Controls

2.1 Integrated Control

All units are equipped with an integrated control, located under the unit, in front of
the electrical compartment. Use the push button (1) to control the unit. The LED
(2) will then shows on which mode the unit is in.
Refer to table below to see how to operate the unit using its integrated control.
P
RESS ON PUSH BUTTON
O
NCE
T
WICE
T
HREE
If a problem occurs during the unit operation, its integrated control LED (2) will
blink. The color of the blinking light depends on the type of error detected. Refer to
Section 4.0 Troubleshooting on last page for further details.
B
OOT SEQUENCE
The unit boot sequence is similar to a personnal computer boot sequence. Each
times the unit is plugged after being unplugged, or after a power failure, the unit
will perform a 30-second booting sequence before starting to operate. During the
booting sequence, the integrated control LED will light GREEN or AMBER for
5 seconds, and then will shut off for 2 seconds. After that, the LED will light RED
for the rest of the booting sequence. During this RED light phase, the unit is
checking and resetting the motorized damper position. Once the motorized
damper position completely set, the RED light turns off and the booting sequence
is done.
NOTE: No command will be taken until the unit is fully booted.

2.2 Optional Main Controls

For more convenience, this unit can also be controlled using an optional main wall
control. All the following models can be used, but only one of them can be
connected to the unit.
NOTES: 1. The integrated control must be turned OFF to use an optional main
control.
2. If an optional auxiliary control is used, if activated, this auxiliary
control will override the optional main control.
WARNING
Risk of electric shock. Before performing
any maintenance or servicing, always
disconnect the unit from its power source.
CAUTION
Unscrew both screws to open the electrical
compartment. To completely remove, detach
from its retention wire inside.
No light
OFF or remote controled
Amber light
LOW speed
Green ligh
HIGH speed
Blinking light
See User Manual
Sans lumière
Arrêté ou contrôlé
par contrôle mural
Lumière ambre
Basse vitesse
Lumière verte
Haute vitesse
Clignotant
Voir guide d'utilisation
1 2
VD0182
LED C
T
IMES
AVERTISSEMENT
Danger d'électrocution. Débranchez
toujours l'appareil avant d'entreprendre
des travaux d'entretien ou de réparation.
ATTENTION
Dévisser les deux vis pour ouvrir le compartiment
électrique. Pour retirer complètement, le
détacher de son fil de rétention intérieur.
OLOR
A
MBER
G
REEN
N
L
O
IGHT
3
R
ESULTS
U
L
S
NIT IS ON
OW
U
H
S
NIT IS ON
IGH
U
OFF
NIT IS
PEED
PEED

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

415004150641504