Aftertreatment
No special procedures are required. The exhaust
outlet of the aftertreatment should be capped. Before
storing, the engine and the aftertreatment must be
enclosed in a cover.
Monthly Checks
The crankshaft must be rotated in order to change
the spring loading on the valve train. Rotate the
crankshaft more than 180 degrees. Visibly check for
damage or corrosion to the engine and
aftertreatment.
Ensure that the engine and aftertreatment are
covered completely before storage. Log the
procedure in the record for the engine.
Removal from Storage
1. Install the drive belt, refer to this Operation and
Maintenance Manual, "Alternator and Fan Belts -
Inspect/Adjust" for the tension of the belt.
2. Ensure that the engine oil level is correct. Ensure
that the coolant level is correct. Ensure that the
fuel system is full and the fuel system is primed.
Refer to the Operation and Maintenance Manual,
"Fuel system - Prime " for more information.
3. Turn the power ON and check the operation of the
warning lamps. Start engine, refer to Operation
and Maintenance Manual, "Starting the Engine" for
more information.