Connect the AC battery pack charger to the XRC
(-)
(+)
To prevent moisture from entering the XRC
connector at the charger has a metal-backed sealing o-ring and metal-locking nut attached.
Before connecting the charger wiring, trim wire ends back 1/4" and remove associated CHGR Input J17 terminal block
from the digital board (see Figure 36).
Loosen the terminal block securing screws, and insert the black wire into plus (+) terminal (top) and white wire in negative
(-) terminal (bottom). Retighten screws and reinstall the terminal block with wires attached.
Plumb the conduit and associated AC wiring into the AC charger conduit box (see Figure 38). The AC charger is rated at
either 120 Vac 60 Hz or 240 Vac 50 Hz. Connect the 120 V hot and neutral or the two hot wires for 240 V to the AC
charger. Connect the ground wire to the green screw.
Verify that the DC power wires are terminated properly inside the cabinet and verify that the main battery pack is plugged
into J16. Apply AC power to the AC charger.
Monitor DC charging voltage by observing the XRC
G4
using the supplied sealing ring and nut (see Figure 37).
SEALING
BLK
RING
RED
NUT

Figure 37: DC wiring instructions

G4
after installing the AC battery pack charger, be certain that the associated

Figure 38: AC wiring instructions

G4
display. The LCD should indicate: CHARGER 13.0 - 13.5 VOLTS.
XSeriesG4 Remote Controller User's manual 2103334 Rev. AB | 35