Champion 100192 Owner's Manual

2 inch chemical water transfer pump with clear water fittings

Advertisement

Quick Links

2 INCH CHEMICAL
WATER TRANSFER PUMP
WITH CLEAR WATER FITTINGS
SAVE THESE INSTRUCTIONS
Important safety instructions
are included in this manual.
MODEL NUMBER
100192
MADE IN CHINA
REV 100192-20180831
OWNER'S MANUAL
12039 Smith Ave.
Santa Fe Springs CA 90670
USA / 1-877-338-0999
www.championpowerequipment.com

Advertisement

Table of Contents
loading

Summary of Contents for Champion 100192

  • Page 1 2 INCH CHEMICAL WATER TRANSFER PUMP WITH CLEAR WATER FITTINGS MODEL NUMBER 100192 12039 Smith Ave. SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670 Important safety instructions USA / 1-877-338-0999 MADE IN CHINA are included in this manual. REV 100192-20180831 www.championpowerequipment.com...
  • Page 2 AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods.
  • Page 3: Table Of Contents

    100192 2 INCH CHEMICAL WATER TRANSFER PUMP WITH CLEAR WATER FITTINGS TABLE OF CONTENTS Introduction ......
  • Page 4: Introduction

    Congratulations on your purchase of a Champion Power Equipment product. Champion Power Equipment and Champion Engine Technology designs, builds, and supports all of our products to strict specifications and guidelines. With proper product knowledge, safe use, and regular maintenance, this product should bring years of satisfying service.
  • Page 5: Manual Conventions

    100192 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment. Follow all safety messages to avoid or reduce the risk of serious injury or death.
  • Page 6: Safety Rules

    100192 ENGLISH SAFETY RULES WARNING DANGER Read this manual thoroughly before operating your Rotating parts can entangle hands, feet, hair, clothing chemical pump. Failure to follow instructions could and/or accessories. result in serious injury or death. Traumatic amputation or severe laceration can result.
  • Page 7 100192 ENGLISH SAFETY RULES WARNING DANGER Fuel and fuel vapors are highly flammable and DO NOT pump salt, sludge, sewer, sea, or any other type of water containing solid material. extremely explosive. Fire or explosion can cause severe burns or death.
  • Page 8: Controls And Features

    100192 ENGLISH CONTROLS AND FEATURES Read this owner’s manual before operating your chemical pump. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. Chemical Pump Fuel Tank – 0.9 gal. (3.4 L) capacity fuel tank.
  • Page 9: Parts Included

    100192 ENGLISH CONTROLS AND FEATURES Parts Included Your model 100192 gasoline powered chemical pump ships with the following parts: Other – Oil Funnel ......
  • Page 10: Assembly

    100192 ENGLISH ASSEMBLY Add Engine Oil Cont’d. Your chemical pump requires some assembly. This unit ships from our factory without oil. It must be properly NOTE serviced with fuel and oil before operation. If you have any questions regarding the assembly of your Check oil often during the break-in period.
  • Page 11: Add Fuel

    100192 ENGLISH ASSEMBLY Add Fuel Cont’d. Add Fuel 1. Use clean, fresh, regular unleaded fuel with a NOTE minimum octane rating of 85 and an ethanol content Our engines work well with 10% or less ethanol blend of less than 10% by volume.
  • Page 12: Operation

    100192 ENGLISH OPERATION Chemical Pump Location Pumping Place the chemical pump in a well ventilated area. DO WARNING NOT place the chemical pump near vents or intakes where exhaust fumes could be drawn into occupied ONLY liquid materials, chemicals and pesticides or confined spaces.
  • Page 13: Pesticides

    100192 ENGLISH OPERATION Pumping Cont’d. Starting the Engine Cont’d. Pesticides - This pump may be used to pump certain pesticides, but must follow any warnings, cautions and directions for that specific pesticide(s). Pesticides are hazardous chemicals that must be handled with care and caution at all times.
  • Page 14: Stopping The Engine

    To alleviate high altitude issues other than the natural If the engine will not be used for a period of two (2) power loss, Champion Power Equipment can provide a weeks or longer, please see the Storage section for high altitude carburetor main jet. The alternative main proper engine and fuel storage.
  • Page 15: Maintenance And Storage

    100192 ENGLISH MAINTENANCE AND STORAGE The owner/operator is responsible for all periodic Oil Cont’d. maintenance. WARNING Never operate a damaged or defective chemical pump. WARNING Improper maintenance will void your warranty. Spark Plugs 1. Remove the spark plug cable from the spark plug.
  • Page 16: Cleaning

    Contact our help line at 1-877-338-0999 to locate the Engine Stored for Less than 30 Days nearest Champion Power Equipment certified service dealer 1. Allow the engine to cool completely before storage. 2. Clean engine according to the Maintenance section.
  • Page 17: Chemical Pump Storage

    100192 ENGLISH MAINTENANCE AND STORAGE Chemical Pump Storage 1. Allow the chemical pump to cool completely before storage. 2. Turn off the fuel supply at the fuel valve. 3. Drain the pump chamber thoroughly. 4. Clean the chemical pump according to the instructions in the Maintenance section.
  • Page 18: Troubleshooting

    100192 ENGLISH TROUBLESHOOTING Problem Cause Solution Chemical pump will not start No fuel Add fuel Faulty spark plug Replace spark plug Chemical pump will not start; Chemical Low oil level Fill crankcase to the proper level; place pump starts but runs roughly water transfer pump on a flat, level surface...
  • Page 19: Specifications

    – Max Delivery Volume ..154 gal/min (583 L/min) Your Champion Power Equipment product is designed – Gross Weight ....63.9 lb. (29 kg) and rated for continuous operation at ambient –...
  • Page 20: Parts Diagram

    100192 ENGLISH SPECIFICATIONS Parts Diagram...
  • Page 21: Parts List

    100192 ENGLISH Parts List Part Number Description 26.106 Engine 1.6175.06 Nut M6 1.97.1.06 Washer Ø6 222.251303.01 Base, Pump 2.08.059 Bolt 5/16-24 x 30 222.251403.03 Seal, Water Seal 222.250300.01 Water Seal, EPDM + Silicon Carbide 222.251301.01 Friction-Piece, Silicon Carbide 222.251302.01 Seal, EPDM 2.14.021...
  • Page 22: Engine Parts Diagram

    100192 ENGLISH SPECIFICATIONS Engine Parts Diagram...
  • Page 23: Engine Parts List

    100192 ENGLISH Engine Parts List Part Number Description Part Number Description 1.5789.0608 Flange Bolt M6 x 8 23.040017.00 Oil Seal, Valve 22.061100.00.2 Cover, Recoil Starter, Black 21.040003.00 Spring, Valve 21.061005.00 Spring, Recoil Starter 21.040007.00 Retainer, Exhaust Valve Spring 2.10.003.1 Rope Ø4 x 1550, Black 21.040001.00...
  • Page 24 To register your product for warranty and FREE lifetime call center beyond the manufacturer’s control. technical support please visit: – Problems caused by parts that are not original Champion Power https://www.championpowerequipment.com/register Equipment parts. To complete registration you will need to include a copy of the When applicable, this warranty does not apply to products used for purchase receipt as proof of original purchase.
  • Page 25 United States Environment Protection Agency (U.S. EPA) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with U.S. EPA emission regulations. YOUR WARRANTY RIGHTS AND OBLIGATIONS: The US EPA AND CPE are pleased to explain the Federal Emission Control Systems Warranty on your 2018 small off-road engine (SORE) and engine powered equipment.
  • Page 26 EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1997 and later model year small off-road engines (SORE). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
  • Page 27 You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.

Table of Contents