Specifications
Indoor Units
Models
Outdoor Units
Capacity
Rated (Min.~Max.)
Moisture Removal
Running Current (Rated)
Power Consumption
Rated (Min.~Max.)
Power Factor
COP (Rated)
Liquid
Piping
Gas
Connections
Drain
Heat Insulation
Indoor Units
Front Panel Color
Air Flow Rate m³/min
(cfm)
Type
Fan
Motor Output
Speed
Air Direction Control
Air Filter
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Temperature Control
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/L/SL
Sound
Sound Power H
Outdoor Units
Casing Color
Type
Compressor
Model
Motor Output
Type
Refrigerant
Oil
Charge
Type
Refrigerant
Charge
m³/min
Air Flow Rate
(cfm)
Type
Fan
Motor Output
Running Current (Rated)
Power Consumption (Rated)
Power Factor
Starting Current
Dimensions (H×W×D)
Packaged Dimensions (H×W×D)
Weight
Gross Weight
Operation
H/L
Sound
Sound Power
Drawing No.
Notes:
Outdoor ; 35°CDB/24°CWB
10
kW
Btu/h
6,820 (4,430~8,900)
kcal/h
1,720 (1,120~2,240)
L/h
A
W
%
W/W
mm
mm
mm
H
M
L
SL
W
Steps
A
W
%
mm
mm
kg
kg
dBA
dBA
W
L
kg
H
L
W
A
W
%
A
mm
mm
kg
kg
dBA
dBA
MAX. interunit piping length: 20m
MAX. interunit height difference: 15m
Amount of additional charge of refrigerant 20g/m for piping length exceeding 10m
The data are based on the conditions shown in the table below.
Cooling
Indoor ; 27°CDB/19°CWB
Outdoor ; 7°CDB/6°CWB
FTXS20D(2)VML
RXS20D(2)VMB
Cooling
2.0 (1.3~2.6)
0.9
2.7
490 (300~830)
78.9
4.08
φ 6.4
φ 9.5
φ18.0
Both Liquid and Gas Pipes
FTXS20D(2)VML
Silver Line
8.7 (307)
6.7 (237)
4.7 (166)
3.9 (138)
Cross Flow Fan
5 Steps, Silent, Auto
Right, Left, Horizontal, Downward
Removable / Washable / Mildew Proof
0.16
35
95.1
Microcomputer Control
283×800×195
265×855×340
38 / 25 / 22
56
RXS20D(2)VMB
Ivory White
Hermetically Sealed Swing Type
1YC23NXD#A
FVC50K
0.375
R410A
36.2 (1,278)
25.7 (907)
Propeller
2.54
455
77.9
550×765×285
589×882×363
46 / 43
61
3D049111A
Heating
Piping Length
Indoor ; 20°CDB
7.5m
Heating
2.7 (1.3~4.1)
9,210 (4,430~14,000)
2,320 (1,120~3,530)
3.6
660 (290~1,300)
79.7
4.09
9.4 (332)
7.6 (268)
5.8 (205)
5.0 (177)
40
0.16
35
95.1
9
12
38 / 28 / 25
56
600
0.8
32.6 (1,151)
30.6 (1,080)
31
3.44
625
79.0
3.6
30
35
47 / 44
62
SiEBE04-507
230V, 50Hz
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications

Hide quick links:

Advertisement

Table of Contents