SiEBE04-507
Step
3. Removing the titanium
apatite photocatalytic air-
purifying filter
1
The titanium apatite
photocatalytic air-
purifying filter is
attached to the back of
the air filter.
2
Remove the titanium
apatite photocatalytic
air-purifying filter frame
by bending the air filter
and unfastening the
projections from the air
filter frame.
3
Remove the titanium
apatite photocatalytic
air-purifying filter from
its frame (at 5 positions)
by bending it.
Removal Procedure
Procedure
Air filter
The titanium apatite
photocatalytic air-purifying
filter is not marked for
difference between the right
and left sides.
Titanium apatite
photocatalytic
air-purifying filter
(R4309)
Projections
(R4310)
(R4311)
Indoor Unit