5.7 Product preservation

Important
• If the engines are not to be used for 6 months, they must
be protected by carrying out the operations described in
Engine storage (up to 6 months) (Par. 5.10).
• If the engine is still not in use after the first 6 months, it is
necessary to carry out a further operation to extend the
protection period (more than 6 months) (Par. 5.11).
• If the engine is not to be used for an extended period, the
protective treatment procedure must be repeated within 24
months of the previous one.

5.8 Engine storage (up to 6 months)

Before storing the engine check that:
• The environments are not humid or exposed to bad weather.
Cover the engine with a proper protective sheet against
dampness and atmospheric contaminants.
• The place is not near electric panel.
• Avoid storing the engine in direct contact with the ground.

5.9 Engine storage (over 6 months)

Follow the steps described in Par. 5.10.
1 - Engine oil replacement
(Par.
2 - Refuel with fuel additives for long storage.
The following additives are recommended:
DEFA Fluid Plus (Pakelo Lubricants),
Diesel Treatment (Green Star),
Top Diesel (Bardhal),
STP
Diesel Fuel Injector Treatment.
®
3 - With expansion tank:
make sure that the coolant is up to the maximum level.
4 - Without expansion tank:
Follow the steps described in
5 - Start the engine and keep it idle at minimum speed for 2
minutes.
6 - Bring the engine to 3/4 of the maximum speed for 5÷10
minutes.
7 - Turn off the engine.
8 - Completely empty the fuel tank.
9 - Spray SAE 10W-40 on the exhaust and intake manifolds.
10 - Seal the exhaust and intake ducts to prevent foreign
bodies from entering.
11 - When cleaning the engine, if using a pressure washer
or steam cleaning device, avoid directing the nozzle on
electrical components, cable connections and sealed
rings (oil seals etc).
ED0053031100
_00
INFORMATION ABOUT MAINTENANCE
6.1).
Par.
4.6.
If cleaning engine with a pressure washer or steam
cleaner, it is important to maintain a minimum distance of
at least 200mm between the surface to be washed and the
nozzle - avoiding absolutely electrical components.
12 - Treat non-painted parts with protective products.
If the engine protection is performed according to the
suggestions indicated no corrosion damage should occur.

5.10 Engine starting after storage

1 - Remove the protective sheet.
2 - Use a cloth soaked in degreasing product to remove the
protective treatment from the external parts.
3 - Inject lubricating oil (no more than 2 cm
ducts.
4 - Refill the tank with fresh fuel.
5 - Make sure that the oil and the coolant are up to the
maximum level.
6 - Start the engine and keep it idle at minimum speed for a
two about minutes.
7 - Bring the engine to 75% of maximum rated speed for 5 to
10 minutes.
8 - Stop
the
engine
while
(Par.
6.1), discharge the protective oil in a suitable
container.
Warning
• Over time, lubricants and filters lose their properties, so it is
important consider whether they need replacing, also based
on the criteria described in
9 - Replace the filters (air, oil, fuel) with original spare parts.
10 - Pour new oil
(Par.
4.5) up to the maximum level.
11 - Empty the cooling circuit completely and pour in the new
coolant up to the maximum level
5
) into the intake
3
the
oil
is
still
Tab.
5.2.
(Par.
6.4).