Sauer Danfoss JS6000 User Manual page 9

Xy-axis joystick function block
Table of Contents

Advertisement

JS6000_XY Function Block Configuration Settings
Input
Type
Range
LatchPFlt
BOOL
——
LatchInFlt
BOOL
——
CalWindow
——
0–3000
CalDetectTm
——
0–65535
Dband_Hi
——
0–4999
PLUS+1 Compliant JS6000 XY-Axis Joystick Function Block
User Manual
JS6000_XY Function Block
Description
The function block sets a Status condition when it receives an invalid setup or calibration parameter.
The block disables the signal on the Out pin that is related to the abnormal parameter.
The LatchPFlt (Latch Parameter Fault) sets when the block enables the signal after the condition clears.
– T—the block enables the Out signal only after you repower the controller.
– F—the block immediately enables the Out signal.
The function block sets a Fault condition when it receives an invalid input.
The block disables the Out signal that is related to the abnormal input.
The LatchInFlt (Latch Input Fault) sets when the block enables the signal after the condition clears.
– T—the block enables the Out signal only after you repower the controller.
– F—the block immediately enables the Out signal.
The CalWindow (Calibration Window) sets the width of three calibration windows.
These windows center on the default CalHi, CalMid, and CalLow calibration values.
For more information, see
About Calibration Windows and Default Calibration Values
The default calibration values are set in the Memory page. They are the Default inputs to the three Non-Volatile
Memory Dynamic with Default components in this page.
During autocalibration, input voltages must be within these windows for the function block to capture them as
valid calibration values.
The CalWindow value is set as percentage of SnsrPwr.
1000 = 10.00%.
The CalDetectTm (Calibration Detect Time) sets the time during autocalibration that input voltages must remain
in each calibration window for the function block to capture them as valid CalHi, CalMid, and CalLow calibration
values.
1000 = 1000 ms.
The Dband_Hi (Deadband High) sets the width of an upper deadband.
An input voltage within this band produces a +100% output.
This deadband extends below the CalHi calibration value.
The function block sets the width of the Dband_Hi as a percentage of the difference between the CalHi and
CalMid calibration values.
For more information, see
About Calibration Values and Deadbands
1000 = 10.00%.
11007142 · Rev BA · September 2011
on page 11.
on page 13.
9