Mc Controller-Pushbutton Input Configuration; Mc Controller-How To Configure A Digin For A +5 Vdc Activated Pushbutton Input - Sauer Danfoss JS6000 User Manual

Xy-axis joystick function block
Table of Contents

Advertisement

MC Controller—Pushbutton Input Configuration
PLUS+1 Compliant JS6000 XY-Axis Joystick Function Block
User Manual
JS6000_XY Function Block
You can route a pushbutton input to a Btn pin on the function block through:
A DigIn on your controller.
An MFIn on your controller.
A DigAn on your controller.
You must configure the input that you use to accept a pushbutton input.
MC Controller—How to Configure a DigIn for a +5 VDC Activated Pushbutton Input
T
By default, a DigIn on a typical PLUS+1 GUIDE template requires no configuration
changes to accept an input from a pushbutton wired to +5 VDC common sensor power.
However, it is a good idea to verify the configuration of a DigIn.
1. In the GUIDE template, enter the Inputs page.
2. Enter the DigIn page that configures the pushbutton input.
3. Make sure that the PinConfig value is 2.
11007142 · Rev BA · September 2011