Configuration Settings

JS6000_XY Function Block Configuration Settings
Input
Type
Range
CalMode
——
0–3
RturnToNeut BOOL
——
8
PLUS+1 Compliant JS6000 XY-Axis Joystick Function Block
User Manual
JS6000_XY Function Block
Enter the JS6000_XY page to change the JS6000_XY function block's configuration
settings.
When working with configuration settings for PLUS+1 compliant joysticks, note that:
Configuration inputs with a _Base suffix configure the joystick base.
Configuration inputs with a _Grip suffix configure the joystick grip.
Description
Selects the CalMode (Calibration Mode) that sets the CalHi, CalMid, and CalLow values.
– 0—download values with the PLUS+1 GUIDE Service Tool.
– 1—capture values using autocalibration or directly download values with the PLUS+1 GUIDE Service Tool.
In autocalibration, you operate the joystick and the block captures values that fall within defined windows.
– 2—the controller uses only the Default calibration values in the Memory page.
– 3—erases all calibration values.
RturnToNeut (Return to Neutral) sets when the function block enables its Out signals after a controller startup,
calibration, or a Fault or Status condition.
– T—the block enables its Out signals only after all its inputs return to neutral.
– F—the block immediately enables its Out signals.