Sauer Danfoss JS6000 User Manual page 5

Xy-axis joystick function block
Table of Contents

Advertisement

JS6000_XY Function Block Inputs
Input
Type
Range
X
——
0–5260 mV
Y
——
0–5260 mV
PLUS+1 Compliant JS6000 XY-Axis Joystick Function Block
User Manual
JS6000_XY Function Block
Description
The voltage input to the X pin indicates the position of the joystick base on its x-axis.
The default:
– CalLow calibration value for X is 10% of the SnsrPwr voltage. An X input at this voltage outputs an
X_Axis_Psn signal of -100%.
– CalMid calibration value for X is 50% of the SnsrPwr voltage. An X input at this voltage outputs an
X_Axis_Psn signal of 0%.
– CalHi calibration value for X is 90% of the SnsrPwr voltage. An X input at this voltage outputs an X_Axis_Psn
signal of +100%.
The X and Y inputs have identical configuration requirements and calibration values.
The voltage input to the Y pin indicates the position of the joystick base on its y-axis.
The default:
– CalLow calibration value for Y is 10% of the SnsrPwr voltage. A Y input at this voltage outputs an
Y_Axis_Psn signal of -100%.
– CalMid calibration value for Y is 50% of the SnsrPwr voltage. A Y input at this voltage outputs a Y_Axis_Psn
signal of 0%.
– CalHi calibration value for X is 90% of the SnsrPwr voltage. A Y input at this voltage outputs a Y_Axis_Psn
signal of +100%.
The X and Y inputs have identical configuration requirements and calibration values.