Status and Fault Logic

PLUS+1 Compliant JS6000 XY-Axis Joystick Function Block
User Manual
JS6000_XY Function Block
The following table shows how:
The Status output indicates the calibration conditions of the inputs.
During calibration, the related Psn signal on the Out pin is zero.
Status Logic
Condition
Block is OK.
Block is not calibrated.
Block is partially calibrated.
Invalid setup/calibration.
The following table shows how:
The Fault output indicates fault conditions.
Any fault condition sets its related Psn signal on the Out pin to zero.
Fault Logic
Condition
Fault
Block is OK.
0x0000
Input value is too low.
0x8001
Input value is too high.
0x8002
Short circuit.
0x8004
Open circuit.
0x8008
11007142 · Rev BA · September 2011
Status
Psn Signal
Comment
0x0000
±10000.
Normal output of all Psn signals.
0x8001
*Calibration of an input sets its related Psn signal to
0.
0x8002
0*/±10000**.
**A valid input has a related Psn signal of ±10000.
0x8008
Psn Signal
Comment
±10000.
Normal output of both Psn signals.
*An invalid input sets its related Psn signal to 0.
0*/±10000**.
**A valid input has a related Psn signal of ±10000.
7