Should the door handle not close properly, check and if required adjust the "nose" position as
follows:
1. With oven door open, loosen the fixing screws of the "nose"
2. Move the "nose" vertically and fasten it so that when the door is closed it may be inserted in
the handle, completely open (horizontal position) without rubbing.
3. After adjustment, with closed door the handle must be in vertical position (the end portion of
the "nose" must be perfectly horizontal).
Warning
The door handle must only be adjusted after positioning the oven in the correct way
(paragraphs 4.6)
10.4 Thermal safety device reset
You can have access to this device by removing the lower back of the appliance. After removing
the protective cover of the device, reset it by pressing the corresponding red button.

11. Possible faults

Type of fault
Control panel
completely off (the
oven does not work)
Cooking cycle set: the
oven does not work
Automatic humidifier
ON: no steam is
produced in the
cooking chamber
Door closed: steam
comes out of the seal
The oven does not
cook evenly
Lighting lamp in the
cooking chamber does
not work
The thermo safety
device turns on in
continuous
pag 20 _________________________________________________________________________________________
Cause
- Incorrect electric connections to the mains
- No mains voltage
- Thermal break safety device tripped
- Door open or ajar
- Damaged door microswitch
- Incorrect connection to water mains
- Cut-off cock closed
- Blocked water inlet filter
- Damaged water inlet solenoid
- Seal not fitted correctly
- Damaged seal
- Handle prong loosened
- One of the motors is blocked or turns
slowly
- The motors do not go into reverse
- Heating element not powered or is
damaged
- Damaged lamp
- Damaged lamp feeder
- Device damaged
- Regulating thermo state damaged
Corrective action
- Check the mains connection
- Restore mains voltage
- Reset the thermal break safety device
- Close the door
- Contact a qualified technician to repair
the sensor
- Check the connection to water mains
- Check the cut-off cock
- Clean the filter
- Contact a qualified technician to repair
the solenoid
- Check the seal fitting
- Contact a qualified technician to repair
the seal
- Contact a qualified technician to repair
the prong
- Contact a qualified technician to repair
the motor
- Contact a qualified technician to repair
the motor
- Contact a qualified technician to repair
the element
- Change the lamp
- Contact a qualified technician to repair
the feeder
- Contact a qualified technician to repair
the feeder
- Contact a qualified technician to repair
the feeder