General Purpose A/D - Motorola C24 CDMA 1X Hardware Interface Manual

Hide thumbs Also See for C24 CDMA 1X:
Table of Contents

Advertisement

Applicant: Motorola, INC
Parameter
Conditions
Temperature
Operating range
Range
Tolerance
Resolution
2.9.3

General Purpose A/D

The module provides 3 additional general purpose A/D (GPAD) signals for customer application use.
Each A/D signal can monitor a separate external voltage and report its measured level independently to
the application, through the AT command interface. The A/D Signals are available at the connector in the
following pins: 37, 43 and 47.
The GPAD signals can sense a DC voltage level of 0 – 2.3 V, which is converted internally to a 10-bit
digital value.
TABLE 22 – GPAD Specifications
Parameter
Conditions
Input Voltage
Sampling
Range
Resolution
Min
-30
Min
0
0.05
Motorola General Business Use
Page 31 of 36
FCC ID: IHDP56JE1
C24 Hardware Interface Manual
Typ
Max
Units
85
°C
5
%
1
°C
Typ
Max
Units
2.9
V
2.5
V
10
mV