Battery Protection - EFOY Pro 600 Manual

Hide thumbs Also See for Pro 600:
Table of Contents

Advertisement

5. Operation
Off

Battery protection

Off
Battery protection -> to shut down
press off
have elapsed. The message "Shutting down" will
appear in the display. Leave the fuel cartridge and the
battery connected during this time.
Please note that the fuel cell will not charge the
battery automatically if it is switched off. The unit
needs to be switched on manually and can only start
up if it is connected to an intact battery and full fuel
cartridge.
5.9
Battery protection
The EFOY Pro fuel cell has an integrated battery
protection function. This function prevents deep
discharge of the battery when the operating mode is set
to "Off".
Battery protection is automatically activated when the
battery voltage is lower than 11.2 V (24.4 V) for more
than 15 minutes. The battery protection charging mode
ends when the voltage reaches 12.8 V (25.6 V).
This function only serves to protect the battery, and
does not recharge it.
Press the
battery protection function starts. The function is
reactivated automatically when the unit is switched on
or operated in automatic mode.
Note: If you stop protective charging manually, battery
protection is deactivated until the fuel cell is started
again. Deep discharge can damage your battery. If
battery protection starts repeatedly, please check
your system.
Battery protection only functions when a full EFOY
fuel cartridge is connected.
35
button to switch off the fuel cell after the

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pro 1600Pro 2200Pro 2200 xt