4. Installation

+45 °C
–20 °C
HEAT
STACK
EXCHANGER
4.
Installation
4.1

Installation Space Requirements

WARNING
Securely fasten unit and fuel cartridges when using on
board motor vehicles.
Do not operate unit if there is danger of explosion.
Unit is not watertight. Make sure that no water can
enter.
Keep unit and fuel cartridges away from children,
temperatures in excess of 45 °C and direct sunlight.
Make sure when choosing an installation space, that
the temperature ranges between –20 °C and +45 °C.
The unit requires air from the outside and generates
off-heat that needs to be conducted to the outside.
Please take this into account when considering
possible locations.
1
Air intake for installation space
2
Air intake for heat exchange and for stack
3
Off-heat from heat exchanger
(see chapter 4.3, page 17)
4
Exhaust from stack
(see chapter 4.4, page 18)
5
Off-heat from installation space
14