Table of Contents

Advertisement

Contents

Contents
Contents ..................................................................................................... 1
1
Introduction .................................................................................... 4
Foreword ..................................................................................... 4
Contact details ............................................................................. 4
2
Safety Information .......................................................................... 5
Explanation of safety alert signal words ...................................... 5
General safety instructions .......................................................... 6
Safety instructions for methanol ................................................. 7
Correct use .................................................................................. 9
Certification ............................................................................... 10
Warranty .................................................................................... 11
Disposal and Transportation ...................................................... 12
3
Configuration ................................................................................ 13
Standard equipment .................................................................. 13
Connections ............................................................................... 14
Specifications ............................................................................. 16
4
Installation .................................................................................... 19
Installation space requirements ................................................ 19
Mounting the fuel cell ................................................................ 22
Connecting the off-heat duct ..................................................... 23
Connecting the exhaust hose ..................................................... 25
Installing the fuel cartridge holder ............................................ 27
Electrical connections ............................................................... 28
4.6.1
4.6.2
Installing and connecting the operating panel ........................... 32
4.7.1
4.7.2
5
Operation ...................................................................................... 34
Operation on the device ............................................................. 34
Electrical connection to the battery ................................. 29
Combination with other energy sources .......................... 31
Flush mounting ................................................................ 32
Surface mounting ............................................................. 33
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for EFOY Pro 800 Pro 800 Duo Pro 2400 Pro 2400 Duo

  • Page 1: Table Of Contents

    Contents Contents Contents ..................... 1 Introduction ..................4 Foreword ..................4 Contact details ................4 Safety Information ................5 Explanation of safety alert signal words ........5 General safety instructions ............6 Safety instructions for methanol ..........7 Correct use .................. 9 Certification ................
  • Page 2 Switching off the fuel cell ..........67 5.7.2 Detaching the charge line and data line ......67 5.7.3 Removing the EFOY fuel cartridge ........67 5.7.4 Detaching the exhaust hose and off-heat tube ....68 Maintenance ................. 69 Service ..................69 Long term storage ..............
  • Page 3 Contents Adding EFOY service fluid ............77 Data Interface and Optional Accessories ........79 Data interface functionality............79 Communication Protocols............81 8.2.1 Modbus RTU ..............81 8.2.2 SIO / Plain text ..............93 GSM modem ................94 Fuel cartridge sensor FS1 ............95 Cluster controller CC1 ...............
  • Page 4: Introduction

    Introduction Foreword Thank you for choosing an EFOY Pro fuel cell from SFC Energy AG. We hope you enjoy using your new energy supply system. Before you use the fuel cell for the first time, please read this user man- ual and follow the installation instructions.
  • Page 5: Safety Information

    Safety Information Safety Information Explanation of safety alert signal words DANGER! Indicates an imminently hazardous situation, which, if not avoided, poses a high risk of death or serious physical injury. WARNING! Indicates a potentially hazardous situation, which, if not avoided, poses a medium risk of death or serious physical injury.
  • Page 6: General Safety Instructions

    Keep EFOY Pro fuel cells that have been switched off in frost-free storage or use the automatic antifreeze feature. Do not smoke in the vicinity of the EFOY Pro fuel cell or EFOY fuel car- tridge. Protect from heat and ignition sources. Methanol is highly flam-...
  • Page 7: Safety Instructions For Methanol

    DANGER! Leakage of methanol fumes poses a fire hazard! Do not smoke when re- placing the EFOY fuel cartridge and do not expose it to other ignition sources! Protect EFOY fuel cartridges from temperatures exceeding +50 °C / +122 °F.
  • Page 8 Safety Information WARNING! Methanol is highly flammable! You receive methanol in safe, tested EFOY fuel cartridges, which prevent the contents from escaping if used correctly. The storage and transport of methanol may be subject to statutory regu- lations. For more information, refer to the safety data sheet on methanol, availa- ble on our website at http://www.efoy-pro.com.
  • Page 9: Correct Use

    Safety Information Correct use The EFOY devices produced by SFC Energy AG are automatic charging de- vices for 12 V or 24 V lead accumulators (batteries) or SFC qualified Lith- ium Iron Phosphate batteries (LiFePO4). Please note the following: •...
  • Page 10: Certification

    Declaration of conformity SFC Energy AG, Eugen-Saenger-Ring 7, 85649 Brunnthal, Germany, hereby declares that the EFOY Pro 800, EFOY Pro 800 Duo, the EFOY Pro 2400 and the EFOY Pro 2400 Duo is compliant with the following European Union directives and the European standards: •...
  • Page 11: Warranty

    AG that are valid for the relevant country at the time of purchase. Please note the attached conditions of warranty. Service Please contact our EFOY hotline in relation to any technical questions about EFOY Pro fuel cells. The contact details are provided in chapter 1.2 "Contact details" on page 4. Page 11...
  • Page 12: Disposal And Transportation

    Please note the instructions provided by SFC Energy AG when transporting the device. For information on this, refer to our website or contact the EFOY hotline. The contact details are provided in chapter 1.2 "Contact de- tails" on page 4.
  • Page 13: Configuration

    Configuration Configuration Standard equipment The EFOY Pro fuel cell SET includes the following equipment: Part number Description Device EFOY Pro fuel cell 151 077 056 Operating panel OP2 151 075 033 Data cable DL2 151 905 021 Fuel cartridge holder...
  • Page 14: Connections

    Pin assignment see Data Interface Button LEDs Connection for exhaust hose and fill opening for EFOY service fluid Connector #1 for EFOY fuel cartridge Connector #2 for EFOY fuel cartridge (Only in model “Duo”) Cooling inlet (reverse) Warm-air outlet and connection for off-...
  • Page 15 Configuration Data Interface Description DuoCartSwitch DCS1 RS232 RxD (Receive Data) RS232 TxD (Transmit Data) GND, Ground Battery + Fuel Cartridge Sensor FS1 Remote On M/S (Master/Slave) & Hybrid Page 15...
  • Page 16: Specifications

    Configuration Specifications Performance data Product EFOY Pro EFOY Pro EFOY Pro EFOY Pro 800 Duo 2400 2400 Duo Output power 45 W 45 W 110 W 110 W Output power after 25 W 25 W 80 W 80 W 4500 hours...
  • Page 17 Configuration General data Product EFOY EFOY Pro EFOY Pro EFOY Pro Pro 800 800 Duo 2400 2400 Duo Number of fuel car- 1 (2) 2 (4) 1 (2) 2 (4) tridges (with DCS1) Sound pressure level at a distance of 1 m / 7 m 42 dB(A) / 25 dB(A) (3.3 ft / 23 ft)
  • Page 18 Configuration Equipment Operation On the device or via operating panel with text display Data interface RJ-45 plug for accessories (e.g. interface adapter) Electrical interface MNL plug, 4-prong (e.g.Tyco Electronics Universal Mate-N-Lok – No. 350779) Fuel cartridge Fuel cartridges MT60 (only with M28 adapter) Volume 5 liters /...
  • Page 19: Installation

    EFOY Pro fuel cell will shut down and not produce energy. As soon as the temperature in the installation space fall below +40 °C / +102 °F the EFOY Pro fuel cell will start again fully automatic. CAUTION! The device requires an air supply and generates off-heat and exhaust gases.
  • Page 20 This can be done with additional openings or an additional temperature-controlled fan. • The electrical connections, the fill opening for EFOY service fluid and the fuel cartridge must be easily accessi- ble. Page 20...
  • Page 21 • The EFOY Pro 800 Duo and EFOY Pro 2400 Duo each have two 70 cm / 27.6 in hoses. Make sure that the fuel cartridge is within reach of both connections.
  • Page 22: Mounting The Fuel Cell

    Installation Mounting the fuel cell Select a suitable location for installa- tion as described in chapter 4.1 "In- stallation space requirements" on page 19. Observe the dimensions in chapter 3.3 "Specifications" on page 16. Secure the mounting plate tightly at the desired location.
  • Page 23: Connecting The Off-Heat Duct

    Exhaust air Exhaust gas Sink the screws for the off-heat flange into the holes provided at the air outlet of the EFOY Pro fuel cell. Attach the off-heat bow to the off- heat flange. Use the off-heat bow to conduct warm air sideways or downwards.
  • Page 24 This is guaranteed if you use original EFOY accessories and if the fuel cell is installed correctly by a qualified professional. Attach the external face plate to the...
  • Page 25: Connecting The Exhaust Hose

    Installation Connecting the exhaust hose Within the EFOY Pro fuel cell methanol and oxygen are converted into wa- ter and carbon dioxide. This process creates heat, which needs to be con- ducted to the outside together with water vapor, carbon dioxide, and traces of methanol.
  • Page 26 Installation Feed the exhaust hose from the instal- lation space through to the outside. Use a suitable sealant to seal the hole. Ensure that the exhaust hose has no kinks or blockages and that the ex- haust gases can flow freely out of it. INFO: Keep the exhaust hose as short as possible.
  • Page 27: Installing The Fuel Cartridge Holder

    Installation Installing the fuel cartridge holder • Fuel cartridges and reserve fuel car- tridges must not be placed in front of the inlet or outlet for the off-heat flow. • Do not place any other objects in front of the inlet or outlet for the off-heat flow.
  • Page 28: Electrical Connections

    Installation Electrical connections WARNING! All electrical work must only be carried out by qualified electrical techni- cians in accordance with the relevant legal provisions. Laying cables incorrectly or using the wrong cable size may result in a fire hazard. All connected cables must have sufficient insulation and adequate proof voltage, and the connectors must be scoop-proof.
  • Page 29: Electrical Connection To The Battery

    The EFOY Pro charges the connected battery and the battery supplies the power to the application or to the electrical loads. The EFOY Pro must only be used to charge lead batteries that conform to the technical specifications of the device (see chapter 3.3 "Specifications"...
  • Page 30 EFOY Pro Series Battery Load EFOY Pro fuel cell Connecting line to EFOY Pro fuel cell Extension cable sense line 8m / 26ft (optional accessories) Battery protection in sense line with 2 A fuse Battery Extension cable power line 8m / 26ft (optional accessories)
  • Page 31: Combination With Other Energy Sources

    In the case of a combination with other energy sources it is recommended to adjust the switch-on thresholds of the EFOY Pro so that the device only switches on if solar alone does not provide enough energy (e.g. in winter).
  • Page 32: Installing And Connecting The Operating Panel

    Installation Installing and connecting the operating panel The operating panel displays the current status of the device and is used to operate the EFOY Pro fuel cell. Mount the operating panel in an easily ac- cessible location. 4.7.1 Flush mounting...
  • Page 33: Surface Mounting

    (e.g. Velcro strip). Insert the data line plug into the left socket on the EFOY Pro fuel cell marked "Remote Control". INFO: If the DL2 data line supplied is not...
  • Page 34: Operation

    Operation Operation Operation on the device The integrated LEDs provide an overview of the operating status of the EFOY Pro fuel cell. You operate the device using the buttons. Button Green LED Yellow LED Red LED Button ac- Result Starting state...
  • Page 35: Operation Via The Operating Panel

    5.2.1 Buttons and symbols on the operating panel Buttons/LEDs The buttons and LEDs on the operating panel have the following functions: Switch EFOY Pro fuel cell on/off [menu] Display the main menu. [] Scroll back one level in the menu.
  • Page 36 The fuel cartridge should only be replaced once it has been completely emptied. A cluster icon is displayed for EFOY Pro devices that run in paral- lel (see chapter 8.5 "Cluster controller CC1" on page 96).
  • Page 37: Initial Commissioning

    Operation 5.2.2 Initial commissioning Switch on After connecting the EFOY Pro fuel cell to the oper- ating panel for the first time, the intro screen ap- pears on the display. After a short wait, the language selection appears. Selecting a language Use [][] to select the required lan-...
  • Page 38: Info Screen

    Select the relevant fuel cartridge for each connector. Press [ok] to confirm your selection. If you are using an EFOY Pro Duo fuel cell, "Connector #1" is displayed first. If you con- firm this selection, you can select "Connector #2".
  • Page 39 Press [ok] to confirm your operating mode selection. Operating status Start phase The EFOY Pro fuel cell undergoes a start phase lasting up to 20 minutes. At the end of this phase, it has reached its full rated output. Charging mode The EFOY Pro fuel cell charges the battery.
  • Page 40 7.2 "Errors and solutions" on page INFO: During normal operation, the EFOY Pro fuel cell briefly interrupts power generation several times each hour for max. 30 seconds. A charging current of 0.0 A is displayed when this occurs.
  • Page 41: Main Menu

    Operation 5.2.4 Main menu • Press [menu]. The main menu appears. • Press [][] to select a submenu. • Press [ok] to access the selected submenu. • Press [] to return to the info screen. You can select the following menu options in the main menu: Operating mode For a detailed description, see chapter 5.5 "Operating modes"...
  • Page 42 Press [][] to select the language. Press [ok] to confirm the language selec- tion. Reset The reset function allows you to restart the EFOY Pro fuel cell: • Press [ok] to confirm the restart. • Press [] to cancel the restart and return to the main menu.
  • Page 43: Expert Menu

    Operation 5.2.5 Expert menu CAUTION! Incorrectly set operating parameters may damage the device. This may nullify your warranty. Only use the precise values permitted for the battery parameters and battery protection settings (see page 49). Before installation and operation please check the battery data sheets from the manufacturers permitted battery values.
  • Page 44 LiFePO4 (Lithium iron phosphate) EFOY GO! Press [ok] to access to select a battery type. By choosing the LiFePO4 or EFOY GO! battery type, an icon will be shown on the Info screen. CAUTION! Incorrectly set battery type may damage the battery. This may nullify your warranty.
  • Page 45 Operation Battery parameters You can select the following options in the "Bat- tery parameters" menu: Switch-on delay Switch-on voltage Switch-off voltage Switch-off current Absorption time Max. charge time Min. charge time Altitude up to Hybrid Factory defaults CAUTION! Incorrectly set operating parameters may damage the device. This may nullify your warranty.
  • Page 46 12.3 V for lead-acid batteries, the switch-on volt- age must drop below 12.3 V for at least 60 sec- onds in order for the EFOY Pro fuel cell to start. If loads with a high rate of power consumption are operated temporarily, this value must be set in accordance with the operating times of these loads.
  • Page 47 EFOY Pro fuel cell and/or the battery. Altitude up to The EFOY Pro fuel cell is set by default for a use up to an altitude of 1500 meter. For use at a higher altitude for a longer period, we recom- mend to increase the value.
  • Page 48 In order for the EFOY Pro fuel cell to switch off, the voltage must rise above the set switch-off voltage level, and the current must drop below the set switch- off current or the absorption time must reach the set value.
  • Page 49 Switch-off voltage 28.4 V 27.0 V 29.4 V Switch-off voltage (Hybrid) 29.4 V 27.0 V 31.0 V Switch-off current EFOY Pro 800 1.0 A 0.25 A 5.0 A EFOY Pro 2400 2.0 A 1.0 A 5.0 A Switch-on delay 60 s...
  • Page 50 Min. charge time 30 min 30 min 180 min Max. charge time 48 h 120 h Altitude up to 1500 m 2000 m Permitted value ranges for EFOY GO! (12 V) Factory Min. Max. User-de- defaults fined value: Switch-on voltage 12.4 V 12.0 V...
  • Page 51 The battery protection function provides deep discharge protection for the battery, even when the EFOY Pro fuel cell is switched off and does not take over the charging function. You can select the following menu options in the "Battery protection"...
  • Page 52 Please check your system if the fuel cell repeatedly switches back to battery protection. Either the battery has already been damaged or too much energy has been discharged. INFO: Battery protection only works if a full EFOY fuel cartridge is connected. Page 52...
  • Page 53: Remote Control Via Computer

    Press [ok] to confirm or [] to cancel. Remote control via computer You can also control the EFOY Pro using a computer. Remote control is also possible using an optional modem. The same operating functions available via the operating panel are also available via the data interface (see chapter 5.2 "Operation via the operat-...
  • Page 54: Fuel Cartridges

    Please refer to the information about methanol provided in chapter 2 "Safety Information" on page 5. Keep all EFOY Pro fuel cells and EFOY fuel cartridges out of reach of chil- dren, even when empty or only partly full. Page 54...
  • Page 55 Operation Inserting the fuel cartridge Insert a new, full, and sealed original EFOY fuel cartridge into the fuel car- tridge holder. INFO: Always place the fuel cartridge in the fuel cartridge holder with the con- nector facing upwards. Exception: M28 fuel cartridge (see "Connecting the M28 fuel cartridge"...
  • Page 56 (see chapter 5.4.2 "Selecting a fuel cartridge" on page 58). Connecting the M28 fuel cartridge Screw the EFOY Pro fuel cartridge connector (1) to the M28 adapter (2). Screw the M28 adapter (2) onto the M28 fuel cartridge (3).
  • Page 57 Removing the fuel cartridge Unscrew the fuel cartridge connector from the empty EFOY fuel cartridge. Use the screw cap to seal each EFOY fuel cartridge securely after use. Open the belt. Remove the empty EFOY fuel car- tridge.
  • Page 58: Selecting A Fuel Cartridge

    When you select the "Fuel cartridge" submenu in the main menu, the dis- play shows the fuel cartridges already enabled and the device connectors. The connectors are displayed according to whether you are using an EFOY Pro or EFOY Pro Duo device. INFO: If you have not connected a full fuel car- tridge, disable the fuel gauge by selecting "Disable fuel gauge"...
  • Page 59 Operation You can select the following actions in the con- nector submenu: Cartridge: A single fuel cartridge is to be used at the connector. The associated fuel cartridge is displayed at the highest level of the menu. DuoCartSwitch: A DuoCartSwitch is to be used at the con- nector.
  • Page 60: Operating Modes

    Operation Operating modes The EFOY Pro fuel cell can be operated in one of the following modes: • Automatic • Manual On • Manual Off • External control • Hybrid 5.5.1 Automatic Automatic mode starts as soon as you connect the device to the battery.
  • Page 61: Manual On

    After reaching the switch-off threshold the EFOY Pro fuel cell will switch into automatic mode. Please note: The EFOY Pro fuel cell can only start if it is connected to an intact battery and a filled fuel cartridge. The EFOY Pro fuel cell does not switch on if the battery is damaged or has been deeply discharged.
  • Page 62: Manual Off

    Wait until the shutdown procedure has fin- ished and "Shutdown procedure" is no longer displayed on the info screen. The EFOY Pro fuel cell shuts down in a con- trolled manner when you press [ok]. This may take some time, to ensure that all pro- tective features are applied.
  • Page 63: External Control

    Operation 5.5.4 External control The EFOY Pro fuel cell can also be controlled externally. In that case, the automatic charge control mechanism will be partly or totally deactivated. For an external control the operation mode "External control" must be en- abled.
  • Page 64: Remote On / Off

    5.5.5 Remote On / Off The EFOY Pro fuel cell can be switched on or off externally using one of two methods. One option is by using a switching contact on Pin 7 at the Data Interface plug, e.g. a solar charger. The second option is a software signal.
  • Page 65: Hybrid

    5.5.6 Hybrid The EFOY Pro can be set into Hybrid mode by a voltage signal or a software control. In this operation mode all parameters are disabled, like switch-on voltage or battery protection. Only the frost protection mode is an excep- tion, this will remain enabled.
  • Page 66: Automatic Antifreeze Feature

    To start and stop the EFOY Pro fuel cell a positive voltage signal must be connected to Pin 7 (Remote On) or via software SIO command REMOTE ON/OFF or Modbus address 41030 (see chapter 5.5.5 Re-...
  • Page 67: Shutdown

    5.7.1 Switching off the fuel cell Switch off the EFOY Pro fuel cell via the operating panel or directly on the device. This is described in chapter 5.5.3 "Manual Off" on page 62, or in chapter 5.1 "Operation on the device" on page 34.
  • Page 68: Detaching The Exhaust Hose And Off-Heat Tube

    +1 °C / +34 °F. (See also storage temperature in chapter 3.3 "Specifica- tions" on page 16). If the EFOY Pro fuel cell is exposed to temperatures below 0 °C / 32 °F without connected batteries and sufficiently filled fuel cartridges, it must be defrosted for approximately 24 hours at room temperature before use.
  • Page 69: Maintenance

    +1 °C / +34 °F. (See also storage temperature in chapter 3.3 "Specifica- tions" on page 16). If the EFOY Pro fuel cell is exposed to temperatures below 0 °C / 32 °F without connected batteries and sufficiently filled fuel cartridges, it must be defrosted for approximately 24 hours at room temperature before use.
  • Page 70: Firmware Update

    Maintenance INFO: Use a suitable box for storing the EFOY Pro fuel cell, e.g., the box in which it was delivered. The EFOY Pro fuel cell must be stored in an upright posi- tion only. Firmware update Be sure to check on a regular basis which updates are available for your firmware.
  • Page 71: Troubleshooting

    Safety WARNING! Do not open the EFOY Pro fuel cell! Unauthorized opening of the EFOY Pro fuel cell interferes with safe operation of the device and nullifies the war- ranty and guarantee. The EFOY Pro fuel cell does not contain any parts that you can maintain or repair yourself.
  • Page 72: Errors And Solutions

    Service is required. Pro- Please contact your service partner tect device against frost! or the hotline. Contact details are Please contact EFOY hot- provided in chapter 1.2 "Contact de- line or tails" on page 4. hotline@sfc.com. A restart is required. If Select the "System reset"...
  • Page 73 10 cm / 3.94 in. Then refill the fuel cell with EFOY ser- vice fluid (see chapter 7.3 "Adding EFOY service fluid" on page 77).
  • Page 74 Please refer to the user charged below 0°C. If this is recog- manual of the EFOY GO! nized by the EFOY Pro fuel cell, the charging is interrupted, and the EFOY Pro switches in the manual off mode. A warning is displayed.
  • Page 75 The on-board electrical system in- small or too old. Please cluding the battery has to be check the battery and the checked. The EFOY Pro has meas- battery parameters. Re- ured charging cycles which were place battery if necessary too short. This is an indication of a...
  • Page 76: Errors Without Display Messages

    00800 / 732 762 78* Hotline: +49 89 / 673 592 555 service@sfc.com www.efoy-pro.com *Calls can be placed free of charge from the landline from: Germany, Belgium, Denmark, France, Great Britain, Italy, the Netherlands, Norway, Austria, Sweden, Switzerland and Spain.
  • Page 77: Adding Efoy Service Fluid

    Troubleshooting Adding EFOY service fluid If the EFOY service fluid level is low, the yellow LED on the EFOY Pro fuel cell comes on and the message "Please refill service fluid" appears on the operating panel display. WARNING! If this message is displayed frequently, check that the air supply at the in- stallation location is sufficient.
  • Page 78 Reconnect the charge line to the EFOY Pro fuel cell. When you have finished filling the de- vice, press [ok]. The message is deleted and the EFOY Pro fuel cell returns to its previous operating status, e.g. automatic mode. Be sure to order your next refill of EFOY service fluid from your special- ist dealer in plenty of time.
  • Page 79: Data Interface And Optional Accessories

    DuoCartSwitch DCS1 CAUTION! The data interface cannot be connected directly to a computer. The inter- face adapter is required for this. Connecting the EFOY Pro fuel cell directly to a computer can damage both devices. Data Interface DuoCartSwitch DCS1 RS232 RxD (Recive Data)
  • Page 80 Interface adapter PC (COM interface) The interface adapter IA1 is used to con- nect the EFOY Pro to a computer or modem via the COM connection. The USB adapter enables you to connect the interface adapter to the USB connection if no COM connection is available.
  • Page 81: Communication Protocols

    Data Interface and Optional Accessories Communication Protocols The communication with the EFOY Pro fuel cells is possible via the serial RS-232 data interface. Also a direct modem connection for external con- trol and observation is possible. The operation state can be read, operation parameters can be changed or an external control can be implemented.
  • Page 82 A detailed description is available in the user manual for the interface adapter. Connection to a RS-485 network An RS-485 interface is provides by the optional available EFOY Modbus Adapter. With this adapter an RS 485 network implementation can be real- ized.
  • Page 83 MODBUS address 89. In the case where the serial number ends with 00 the address 100 is set. The MODBUS address of each EFOY Pro fuel cell can be changed via the Operating panel OP2 or with the MODBUS command:...
  • Page 84 A detailed description is available in the user manual for the interface adapter. 8.2.1.1 MODBUS RTU functions The EFOY Pro MODBUS protocol is based on following Modbus specifica- tions: Modbus application protocol V1.1b3 Specific feature: Type RTC (Real Time Clock) Use following bit field definition for decoding RTC types (e.g.
  • Page 85 Data Interface and Optional Accessories Read Register (Function code 0x03) Address Name Description Unit Multiplier Type 30001 Stack temperature °C 0,001 INT32 30003 Tint Internal temperature °C 0,001 INT32 Heat exchanger temper- °C 30005 ature 0,001 INT32 30007 Tdcdc Periphery temperature °C 0,001 INT32...
  • Page 86 Data Interface and Optional Accessories Address Name Description Unit Multiplier Type 30051 SysTime System time 30700 MeOH Methanol consumption 0,000001 UINT32 30702 OnReason Last switch on reason UINT8 30703 OffReason Last switch off reason UINT16 Number of load discon- 30704 LoadDrops nections UINT8...
  • Page 87 Data Interface and Optional Accessories Address Name Description Unit Multiplier Type 30721 Last charging duration LastCyc- FLOAT in manual mode leManual 30723 Last charging duration LastCyc- FLOAT in remote mode leRemote 30725 Cart1 Fill level cartridge port 0.001 INT32 30727 Cart11 Fill level cartridge port 0.001...
  • Page 88 Data Interface and Optional Accessories Write only (Function code 0x10) Address Name Description Value Type 41016 Cartridge Reset Reset fuel gauge of car- 1: C#1 INT16 tridge port to 100 %. 11: C#1 DCS1#1 C: Connector 12: C#1 DCS1#2 DCS1: DuoCartSwitch DCS1 2: C#2 21: C#2 DCS1#1 22: C#2 DCS1#2...
  • Page 89 Data Interface and Optional Accessories Read / Write registers Address Name Description Value Type 40990 IDSELECT Select expert setting See chapter 8.2.1.2 UINT16 “Overview ID list” on page 91. 40991 IDVALUE Read/write expert set- See chapter 8.2.1.2 INT32 ting of selected ID. “Overview ID list”...
  • Page 90 Data Interface and Optional Accessories Address Name Description Value Type 41016 Cartridge Select Activate cartridge port. 1: C#1 INT16 C: Connector 11: C#1 DCS1#1 12: C#1 DCS1#2 DCS1: DuoCartSwitch DCS1 2: C#2 21: C#2 DCS1#1 22: C#2 DCS1#2 41020 Battery Type Set battery type.
  • Page 91 Data Interface and Optional Accessories 8.2.1.2 Overview ID list Profile Name Standard Min. Max. Reaction time for delayed switch on 60 s 300 s Altitude of site up to 1500 m 2000 m Full charge duration / Absorption time 180 min 0 min 300 min Min.
  • Page 92 Max. output time EFOY GO! 24 h 120 h EFOY GO! Battery protection of EFOY GO! 11200 10500 12500 EFOY GO! Charge voltage (hybrid) of EFOY GO! 14400 13800 14600 EFOY GO! Switch on voltage of EFOY GO! 12400 12000 13400...
  • Page 93: Sio / Plain Text

    Data Interface and Optional Accessories 8.2.2 SIO / Plain text Following commands are available in the clear text protocol: Command Description Display command overview. BATTERY Select battery type BATTERYPROTECTION Control battery protection BUTTON Software control of device CARTRIDGE Set/view connected fuel cartridges/DuoCartSwitch CONFIG Set customized operation parameters DEFAULT...
  • Page 94: Gsm Modem

    Data Interface and Optional Accessories GSM modem The optional GSM modem enables you to monitor and control the EFOY Pro fuel cell remotely. It is recommended to use such a solution for autono- mous operation of the EFOY Pro. Functions •...
  • Page 95: Fuel Cartridge Sensor Fs1

    The fuel cartridge sensor FS1 may also be used with fuel cartridges that are partly empty. It sends a signal to the EFOY Pro fuel cell when the fill level falls below the sensor.
  • Page 96: Cluster Controller Cc1

    (e.g. all in auto- Interface adapter IA1 matic mode) and the "External control" op- Computer connection erating mode must be enabled. (COM) All EFOY Pro fuel cells must have the same to fuel cartridge sensor settings to run in parallel. Page 96...
  • Page 97 Data Interface and Optional Accessories The cluster icon is displayed at the bottom right of the display for EFOY Pro devices running in parallel. Remote control (remote-on): The EFOY Pro can be controlled externally using a switching contact on the CC1, which means that the charging mode can be started.
  • Page 98: Duocartswitch Dcs 1

    DuoCartSwitch DCS 1 The DuoCartSwitch enables you to connect two fuel cartridges to the cartridge con- nector of one EFOY Pro fuel cell. The switching valve switches automatically from the fuel cartridge in operation to the reserve fuel cartridge. This means that the autonomy of the application can be dou- bled.
  • Page 99: Appendix

    Appendix Appendix U-I and U-P characteristic *Characteristics valid at 12 V nominal voltage and battery parameter- factory settings of AGM, lead-acid and lead-gel batteries Page 99...
  • Page 100: Output Power Characteristic

    Appendix Output power characteristic Page 100...

Table of Contents